Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Pregnancy in people with type 1 diabetes mellitus (T1D) is well-known to be linked to adverse maternal and neonatal outcomes. Although advancements in diabetes technology, especially hybrid closed-loop (HCL) and advanced hybrid closed-loop (AHCL) systems, have greatly enhanced management for nonpregnant individuals with T1D, pregnant patients still represent a high-risk group that requires further research. Existing trials have shown mixed data in terms of clinically meaningful benefits in glycemic control, but these may be specific to the closed-loop system. Currently, there is one AHCL system approved and available for use in pregnancies complicated by diabetes in the United Kingdom, Europe, and Australia. However, there are no Food and Drug Administration (FDA)-approved closed-loop systems for use during pregnancy in the United States. Existing HCL/AHCL system use is off-label for pregnancy in the United States and often requires assistive techniques to target the tighter glucose levels needed during pregnancy. For patients struggling on multiple daily injections (MDIs) or sensor-augmented pump therapy (SAPT), studies have shown that HCL/AHCLs can reduce the burden of care and enable some people to achieve tighter glucose levels. This review aims to provide an overview of the existing evidence of closed-loop systems in pregnancies complicated by T1D and to discuss their implications and considerations with system use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12061893PMC
http://dx.doi.org/10.1177/19322968251334397DOI Listing

Publication Analysis

Top Keywords

hybrid closed-loop
8
pregnancies complicated
8
closed-loop systems
8
pregnancy united
8
united states
8
tighter glucose
8
glucose levels
8
pregnancy
5
closed-loop
5
provider perspective
4

Similar Publications

Management of diabetes mellitus in hemodialysis is highly complex due to increased glycemic variability and hypoglycemic risk. The use of technologies applied to diabetes has been shown to improve glycemic control, however data in dialysis patients are limited. To describe the efficacy and safety of the minimed 780G AHCL system in a stable hemodialysis patient and during hospitalization in the Intensive Care Unit (ICU).

View Article and Find Full Text PDF

CamAPS FX is a customizable hybrid closed-loop app with a default target glucose of 105 mg/dL. The personal glucose target is user-adjustable in 1 mg/dL increments between 80 and 198 mg/dL in 30-min segments over 24 h. We assessed the impact of different personal glucose targets on glycemic control during real-world use of CamAPS FX in different age-groups.

View Article and Find Full Text PDF

Hybrid pneumatic-hydraulic actuation for MRI-guided robotic stereotactic neurointervention.

Sci Adv

September 2025

Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200336, China.

Stereotactic neurointervention is a common procedure for biopsy, injection, ablation, and implantation of electrodes for deep brain stimulation. Guided by preoperative imaging, conventional approaches are mostly performed manually, lacking operation stability and interactive feedback. The intraoperative magnetic resonance imaging (MRI) guidance enables both structural and functional assessment during operation, permitting interactive adaptation to tissue deformation and avoidance of critical anatomical regions.

View Article and Find Full Text PDF

Continuous glucose monitoring (CGM) has transformed diabetes mellitus management, evolving from a supportive monitoring tool to a central pillar of care. For people with type 1 diabetes and many insulin-treated individuals with type 2 diabetes, CGM now directly informs treatment decisions, especially when integrated with automated insulin delivery (AID) systems. In these hybrid closed-loop systems, sensor data drives real-time insulin adjustments, meaning that accuracy is not just a matter of measurement quality; it is a matter of patient safety.

View Article and Find Full Text PDF

This case report describes a 25-year-old woman with type 1 diabetes mellitus (T1DM) and autoimmune thyroid disease (AITD) who developed Addison disease (AD). The diagnosis was suspected due to a significant decrease in insulin requirement and recurrent hypoglycemia despite adjustments in insulin pump therapy. The patient exhibited typical clinical features of AD, including hyperpigmentation and electrolyte imbalances.

View Article and Find Full Text PDF