Severity: Warning
Message: file_get_contents(https://...@mip+sensor&datetype=edat&usehistory=y&retmax=5&tool=Litmetric&email=readroberts32@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
The structure of nitrofen is stable and resistant to natural degradation, persisting in environments for extended periods. It can accumulate through the food chain, posing risks to human health. Here, we report a sensor based on carbon quantum dots (CQDs) and molecular imprinting technology (CQDs@MIPs). It not only possesses the specificity and stability of MIPs but also incorporates the environmental friendliness and signal amplification capabilities of CQDs, making it an ideal material for the specific detection of nitrofen residues in the environment. The interaction between CQDs@MIPs and nitrofen, as well as the successful removal of nitrofen, were confirmed through transmission electron microscopy (TEM) and Zeta potential analysis, which evaluated the morphology and particle size of the prepared CQDs@MIPs. After binding with nitrofen, the CQDs@MIP sensor exhibited a low detection limit (2.5 × 10 mg·L), a wide detection range (0.01-40 mg·L), a good linear relationship (R = 0.9951), and a short detection time (5 min). The CQDs@MIP sensor also demonstrated excellent stability, with the fluorescence intensity of CQDs@MIPs remaining above 90% of the initial preparation after 20 days. At the same time, Red, Green, Blue (RGB) color model extraction technology is used to fit the color of the sample under different concentrations, and the smart phone application is integrated to realize the visual detection of nitrofen. Furthermore, acceptable accuracy was achieved in real water samples (recovery rates ranging from 84.1% to 115.7%), indicating that our CQDs@MIP sensor has high analytical potential for real samples.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11944888 | PMC |
http://dx.doi.org/10.3390/polym17060816 | DOI Listing |