A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Direct screening and quantification of monoclonal immunoglobulins in serum using MALDI-TOF mass spectrometry without antibody enrichment. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: Monoclonal gammopathies (MGs) are characterized by the presence of monoclonal immunoglobulins (M-proteins). Currently, recommendations for screening of MGs primarily rely on nephelometry, turbidimetry and electrophoresis, which have inherent limitations in sensitivity and throughput. This study aimed to evaluate a novel MALDI-TOF MS-based method, the intact M-protein Screening-Light Chain Assay (iMS-LC Assay), for direct M-protein detection and quantification without antibody enrichment.

Methods: Residual serum samples previously analyzed via serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) were reduced to dissociate light chains from heavy chains. MALDI-TOF MS was then performed to determine the presence of M-protein characteristic pattern. The iMS-LC Assay's analytical sensitivity, specificity, and screening efficacy in healthy populations were assessed.

Results: The iMS-LC Assay successfully detected all M-proteins identified by SPE and demonstrated higher sensitivity in analytical and diagnostic studies. It accurately quantified M-proteins at concentrations below 10 g/L, with a detection limit of 0.2 g/L and the ability to detect levels below 0.1 g/L. For samples with M-protein concentrations >1 g/L, intra-assay and inter-assay coefficients of variation were <10 %. In prospective screening of M-proteins in the healthy population, the iMS-LC Assay detected M-proteins at a prevalence of 3.15 %, higher than IFE (1.87 %) and SPE (0.94 %).

Conclusions: The iMS-LC Assay shows potential to replace SPE and drive advancements in the screening, diagnosis, and monitoring of MGs. Further validation of its clinical sensitivity and specificity is essential to determine its adequacy as a routine screening tool for M-proteins.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2025-0203DOI Listing

Publication Analysis

Top Keywords

monoclonal immunoglobulins
8
ims-lc assay
8
direct screening
4
screening quantification
4
quantification monoclonal
4
immunoglobulins serum
4
serum maldi-tof
4
maldi-tof mass
4
mass spectrometry
4
spectrometry antibody
4

Similar Publications