Article Abstract

Background: Pedicle screw loosening (PSL) is a frequent complication in osteoporotic patients undergoing spinal fixation, yet effective risk assessment methods are limited. This study explores the impact of craniocaudal cyclic load on pedicle screw fixation strength using computed tomography-based finite element analysis (CT-FEA) and evaluates its predictive value for PSL.

Methods: A total of 23 PSL cases (7 men and 16 women) and 29 matched controls were analyzed using CT-FEA. Both a simple axial pullout load and a pullout load with a preset craniocaudal cyclic load were applied to calculate the pullout force. Hounsfield unit (HU) values and volumetric bone mineral density (vBMD) of the screw trajectory were also assessed for osteoporosis evaluation. The pullout force and osteoporotic assessment value were compared between PSL and controls.

Results: Craniocaudal cyclic loading significantly reduced the pullout force (924.3 ± 195.1 N vs. 745.2 ± 188.7 N, p < 0.0001). The PSL group had a lower pullout force under cyclic load (629.6 ± 188.2 N vs. 836.9 ± 131.6 N, p < 0.0001) and lower HU value of screw trajectories (183.7 ± 42.6 vs. 206.7 ± 29.72, p = 0.026) than controls, while simple axial pullout force and vBMD showed no significant differences. Receiver operating characteristic (ROC) analysis indicated that pullout force under cyclic load (AUC = 0.806) was a better predictor of PSL than HU values (AUC = 0.629).

Conclusion: This study demonstrates the critical role of craniocaudal cyclic loading in pedicle screw fixation strength and its predictive value for PSL. Craniocaudal cyclic load reduces screw fixation strength significantly. Pullout force under cyclic load assessed by CT-FEA enhances the predictive accuracy for PSL risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11973385PMC
http://dx.doi.org/10.3389/fbioe.2025.1542352DOI Listing

Publication Analysis

Top Keywords

cyclic load
28
pullout force
28
craniocaudal cyclic
24
pedicle screw
16
screw fixation
12
fixation strength
12
force cyclic
12
load
9
pullout
9
risk assessment
8

Similar Publications

Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.

Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.

View Article and Find Full Text PDF

Climate and health-relevant pollutant emissions from oil and natural gas boilers.

J Air Waste Manag Assoc

September 2025

Interdisciplinary Science Department, Brookhaven National Laboratory, Upton, NY, USA.

Emission factor data for existing heating appliances are being used to estimate achievable emission reductions with emerging heating technologies. However, the emission factors currently being used for modeling were developed prior to low-sulfur fuel standards and rely on a small number of studies, mostly focusing on steady-state operation. In this work, detailed emission measurements of typical heating equipment fired with natural gas and No.

View Article and Find Full Text PDF

Objectives: To investigate how surface treatment affects fracture force, flexural strength, and dynamic loading cycles until failure of 3D-printed restorations.

Materials And Methods: Specimens (7 groups; n = 8 per group) were 3D-printed from an acrylate-based crown and bridge material. After cleaning and post-polymerization, specimens were treated with either silicon carbide paper (1000 grit; 1000/4000 grit) or blasting (AlO; 1 bar/125 µm; 2 bar/125 µm; 1 bar/250 µm) to simulate laboratory treatment.

View Article and Find Full Text PDF

The Development of a Fatigue Failure Prediction Model for Bitumen Based on a Novel Accelerated Cyclic Shear Test.

Materials (Basel)

August 2025

Department of Civil and Environmental Engineering, Washington State University, Pullman, WA 99163, USA.

Fatigue failure of bitumen significantly influences the durability and service life of asphalt pavement. Current fatigue tests have drawbacks such as long durations, unrealistic traffic loading simulations, and difficulties of identifying failure mechanisms. Similarly, existing prediction models are often overly complex and inaccurate.

View Article and Find Full Text PDF

Microbial fuel cells (MFCs) are one of the contributors to the novel sustainable energy generation from organic waste. However, the application of MFCs is limited due to the slow charge transfer between cells and electrodes. This problem can be solved by modifying cells with conductive polymers, such as polypyrrole (PPy).

View Article and Find Full Text PDF