Comprehensive reference ranges for cardiovascular magnetic resonance: time to move on from single centre data?

Int J Cardiovasc Imaging

Division of Cardiovascular Sciences, Faculty of Biology, School of Medical Sciences, Medicine and Health, Manchester Academic Health Science Centre, University of Manchester, Oxford Road, Manchester, M13 9PL, United Kingdom.

Published: May 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cardiovascular magnetic resonance (CMR) provides gold standard, and often unique, measurements of cardiovascular structure, function and tissue character. Fundamental to such capabilities are clearly defined normal ranges. This study aimed to (1) Determine normal ranges for an extensive set of CMR measurements, and the inter-scan reproducibility of these measurements; (2) Determine the impact of common variations in practice, and; (3) Systematically evaluate the findings in the context of published reference ranges. One hundred and 22 healthy adults, including a minimum of 10 males and 10 females per age decile, underwent assessment including CMR (3 T, Siemens). Twenty participants returned for a second CMR. Image analysis was performed using cvi42 by experienced observers. Age- and sex-specific reference ranges, in tabular and normogram formats, and their interscan reproducibility, are provided for left ventricular mass, wall thickness, volumes and ejection fraction; right ventricular volumes and ejection fraction; longitudinal, radial and circumferential LV strains; atrial area, volume and strains; native T1, T2, T2*, aortic distensibility and pulse wave velocity. Measurement reproducibility improved when baseline scans were used for reference, e.g., for basal slice selection. Myocardial T1 was the most reproducible of all CMR measurements. Common variations in practice resulted in significant measurement differences e.g., indexed left atrial volume was larger (47.3 vs 40.3 ml/m, P < 0.0001), and its measurement less variable, when measured from atrial short-axis cine stacks compared to biplanar measurement from 4- to 2-chamber cines. Studies using similar methods to define normal ranges demonstrate clinically-relevant differences in the normal ranges produced. A comprehensive set of age and sex specific CMR reference ranges are provided, along with inter-scan reproducibility and the impact of common variations in practice. Single centre studies, whilst meticulous in design and delivery, result in clinically-relevant variations in normal ranges. We advocate that larger cohorts, including diverse ethnicities, such as the Healthy Hearts Consortium, may be a better approach to defining normal ranges for common CMR measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12075261PMC
http://dx.doi.org/10.1007/s10554-025-03370-5DOI Listing

Publication Analysis

Top Keywords

reference ranges
12
cardiovascular magnetic
8
magnetic resonance
8
normal ranges
8
cmr measurements
8
common variations
8
variations practice
8
volumes ejection
8
ejection fraction
8
ranges
5

Similar Publications

Background: Lateral malleolar avulsion fracture (LMAF) and subfibular ossicle (SFO) are distinct entities that both present as small bone fragments near the lateral malleolus on imaging, yet require different treatment strategies. Clinical and radiological differentiation is challenging, which can impede timely and precise management. On imaging, magnetic resonance imaging (MRI) is the diagnostic gold standard for differentiating LMAF from SFO, whereas radiological differentiation on computed tomography (CT) alone is challenging in routine practice.

View Article and Find Full Text PDF

Rationale And Objectives: Double expression lymphoma (DEL) is an independent high-risk prognostic factor for primary CNS lymphoma (PCNSL), and its diagnosis currently relies on invasive methods. This study first integrates radiomics and habitat radiomics features to enhance preoperative DEL status prediction models via intratumoral heterogeneity analysis.

Materials And Methods: Clinical, pathological, and MRI imaging data of 139 PCNSL patients from two independent centers were collected.

View Article and Find Full Text PDF

Copeptin in the diagnosis and management of renal tubular disorders.

Pediatr Nephrol

September 2025

Pediatric Nephrology Department, Biobizkaia Health Research Institute, Cruces University Hospital, Barakaldo, Spain.

Copeptin, a stable glycopeptide derived from the precursor of arginine vasopressin (AVP), has emerged as a valuable surrogate biomarker for AVP due to its stability and ease of measurement. This narrative review explores the physiological role of copeptin, its utility as a diagnostic and prognostic biomarker in different kidney diseases, and its clinical relevance in renal tubular disorders. The clinical application of copeptin as a diagnostic biomarker is best established in the differential diagnosis of polyuria-polydipsia syndrome (PPS), distinguishing nephrogenic diabetes insipidus (NDI) from central diabetes insipidus (CDI) and primary polydipsia (PP).

View Article and Find Full Text PDF

Background: Differentiating periprosthetic joint infections (PJI) from aseptic failure is challenging in total joint arthroplasty. To date, there is no consensus about the most accurate criteria to diagnose PJI. The current study compares common diagnostic PJI criteria.

View Article and Find Full Text PDF

Background: High-dose-rate (HDR) brachytherapy is essential in the treatment of locally advanced cervical cancer. While Iridium-192 (Ir-192) is commonly used, its short half-life imposes logistical and financial constraints, particularly in low- and middle-income countries (LMICs). Cobalt-60 (Co-60), with a longer half-life and lower operational costs, is a viable alternative.

View Article and Find Full Text PDF