A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Design, Analysis, and Manufacturing of Diffractive Achromatic Optical Systems. | LitMetric

Design, Analysis, and Manufacturing of Diffractive Achromatic Optical Systems.

Micromachines (Basel)

National Key Laboratory of Optical Field Manipulation Science and Technology, Chinese Academy of Sciences, Chengdu 610209, China.

Published: March 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The increasing resolution requirements of imaging optical systems must be satisfied by expanding the aperture of the optical system according to Rayleigh's criterion, and larger apertures of conventional refractive/reflective optics place a greater demand on manufacturing and transportation. Diffractive optics are applied to imaging optics to achieve lightweight design, but the image quality suffers due to their strong negative properties. Therefore, a wide-band imaging system based on the Schupmann achromatic model is proposed in this paper to solve the above problem, and the achromatic performance of the system is guaranteed by the Schupmann achromatic model. The aperture of the relay lens is reduced, since using harmonic diffractive optics as the primary lens results in a much more compact focus compared to the diffractive optics in the same wavelength band. This allows for the lightweight design of the optical system. An 80 mm aperture diffractive optical system covering the 400-900 nm band was designed and fabricated to verify the above theory. The actual resolution of the optical system was 76.196 lp/mm, and the achromatic task was accomplished. The design and experimentation of the wide-band achromatic imaging optical system confirms that the proposed theory is correct, and lays the foundation for the further application of large aperture diffractive telescopes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11945864PMC
http://dx.doi.org/10.3390/mi16030322DOI Listing

Publication Analysis

Top Keywords

optical system
20
diffractive optics
12
optical systems
8
imaging optical
8
lightweight design
8
schupmann achromatic
8
achromatic model
8
aperture diffractive
8
optical
7
system
7

Similar Publications