Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The 12-lead electrocardiogram (ECG) remains a cornerstone of cardiac diagnostics, yet existing artificial intelligence (AI) solutions for automated interpretation often lack generalizability, remain closed-source, and are primarily trained using supervised learning, limiting their adaptability across diverse clinical settings. To address these challenges, we developed and compared two open-source foundational ECG models: DeepECG-SSL, a self-supervised learning model, and DeepECG-SL, a supervised learning model.

Methods: Both models were trained on over 1 million ECGs using a standardized preprocessing pipeline and automated free-text extraction from ECG reports to predict 77 cardiac conditions. DeepECG-SSL was pretrained using self-supervised contrastive learning and masked lead modeling. The models were evaluated on six multilingual private healthcare systems and four public datasets for ECG interpretation across 77 diagnostic categories. Fairness analyses assessed disparities in performance across age and sex groups, while also investigating fairness and resource utilization.

Results: DeepECG-SSL achieved AUROCs of 0.990 (95%CI 0.990, 0.990) on internal dataset, 0.981 (95%CI 0.981, 0.981) on external public datasets, and 0.983 (95%CI 0.983, 0.983) on external private datasets, while DeepECG-SL demonstrated AUROCs of 0.992 (95%CI 0.992, 0.992), 0.980 (95%CI 0.980, 0.980) and 0.983 (95%CI 0.983, 0.983) respectively. Fairness analyses revealed minimal disparities (true positive rate & false positive rate difference<0.010) across age and sex groups. Digital biomarker prediction (Long QT syndrome (LQTS) classification, 5-year atrial fibrillation prediction and left ventricular ejection fraction (LVEF) classification) with limited labeled data, DeepECG-SSL outperformed DeepECG-SL in predicting 5-year atrial fibrillation risk (N=132,050; AUROC 0.742 vs. 0.720; Δ=0.022; P<0.001), identifying reduced LVEF ≤40% (N=25,252; 0.928 vs. 0.900; Δ=0.028; P<0.001), and classifying LQTS syndrome subtypes (N=127; 0.931 vs. 0.853; Δ=0.078; P=0.026).

Conclusion: By releasing model weights, preprocessing tools, and validation code, we aim to support robust, data-efficient AI diagnostics across diverse clinical environments. This study establishes self-supervised learning as a promising paradigm for ECG analysis, particularly in settings with limited annotated data, enhancing accessibility, generalizability, and fairness in AI-driven cardiac diagnostics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11908279PMC
http://dx.doi.org/10.1101/2025.03.02.25322575DOI Listing

Publication Analysis

Top Keywords

foundation models
8
supervised learning
8
public datasets
8
fairness analyses
8
0983 95%ci
8
95%ci 0983
8
0983 0983
8
positive rate
8
95%ci
6
0983
6

Similar Publications

Within this special issue we would like to celebrate 200 years of the Karlsruhe Institute of Technology (KIT) and the former Technical University Karlsruhe/Germany. The Technical University Karlsruhe served, according to the first president of MIT, William Barton Rogers, as the role model for the planned MIT in Boston/USA after he visited Karlsruhe. All authors of this special issue of Macromolecular Rapid Communications have been or are still active in Karlsruhe.

View Article and Find Full Text PDF

Importance: There is an unmet need for long-term, safe, effective, and hormone-free treatments for menopausal symptoms, including vasomotor symptoms (VMS) and sleep disturbances.

Objective: To evaluate the 52-week efficacy and safety of elinzanetant, a dual neurokinin-targeted therapy, for treating moderate to severe VMS associated with menopause.

Design, Setting, And Participants: OASIS-3 was a double-blind, placebo-controlled, randomized phase 3 clinical trial that was conducted at 83 sites in North America and Europe from August 27, 2021, to February 12, 2024, and included postmenopausal women aged 40 to 65 years who were seeking treatment for moderate to severe VMS (no requirement for a minimum number of VMS events per week).

View Article and Find Full Text PDF

An Antibacterial and Electroactive Chitosan-Based Dressing with Dual Stimulus-Responsive Drug Delivery for Wound Healing.

Macromol Rapid Commun

September 2025

Key Laboratory of Textile Science & Technology, College of Textiles, Ministry of Education, Donghua University, Shanghai, China.

Persistent bacterial infections remain a major challenge in wound management. Although drug-loaded wound dressings have gained increasing attention, their therapeutic efficacy is often hindered by uncontrolled drug release and a lack of electrical signal responsiveness. Herein, an antibacterial dressing (CCS-PC) with electroactivity and stimulus-responsive drug release properties was fabricated via electro-assembly, wherein chitosan and ciprofloxacin hydrochloride (CIP) were co-deposited onto polypyrrole (PPy)-coated gauze.

View Article and Find Full Text PDF

Segmentectomies Made Easy series: robotic-assisted right S1 and S2 segmentectomy.

Multimed Man Cardiothorac Surg

September 2025

Department of Thoracic Surgery, New Cross Hospital, Royal Wolverhampton NHS Trust, Wolverhampton, UK

Three-dimensional (3D) guided robotic-assisted thoracic surgery is increasingly recognized as the pioneering approach for the most complex of pulmonary resections, offering high-definition 3D visualization, enhanced instrument augmentation and tremor-free tissue articulation. Compared with open thoracotomy, the robotic platform is associated with reduced peri-operative morbidity, shorter hospital admissions and faster patient recovery. However, sublobar resections such as segmentectomies remain anatomically and technically demanding, particularly in the context of resecting multiple segments, as showcased in this right S1 and S2 segmentectomy.

View Article and Find Full Text PDF

Segmentectomies Made Easy series: robotic-assisted left S1 and S2 segmentectomy.

Multimed Man Cardiothorac Surg

September 2025

Department of Cardiothoracic Surgery, St George’s Hospital, St George's University Hospitals NHS Foundation Trust, London, UK

Three-dimensional (3D) guided robotic-assisted thoracic surgery is increasingly recognized as a leading technique for undertaking the most complex pulmonary resections, providing high-definition 3D visualization, advanced instrument control and tremor-free tissue handling. Compared with open thoracotomy, the robotic platform offers reduced peri-operative complications, shorter hospital stays and faster patient recovery. Nevertheless, sublobar resections, such as segmentectomies, remain both anatomically intricate and technically challenging, particularly when resecting multiple segments, as in this left S1 and S2 segmentectomy.

View Article and Find Full Text PDF