A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Fast Proton NMR Detection of Aqueous Ammonia with Relaxation Agent and Nitrogen Decoupling. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The Haber-Bosch process, which synthesizes ammonia (NH) from nitrogen (N) and hydrogen (H), consumes approximately 2% of the global energy supply. A sustainable alternative is the direct electrochemical conversion of N to NH. The selectivity and activity of the electrocatalysts for this process are assessed by quantifying the NH present in the electrolyte. Compared with other analytical methods, H NMR offers a straightforward approach for detecting NH (by analyzing NH ). H NMR method can also definitely confirm that the detected ammonia originates from the electroreduction of N by comparing results obtained from isotopically labeled N and regular N gases. This capability is unique to the H NMR method, as no alternative approaches offer this level of specificity. However, this method suffers from low sensitivity when measuring NH of low concentration of such as at μM or lower. To address this issue, we developed a novel approach that improves sensitivity by ∼3-fold through the introduction of N decoupling during the H NMR data acquisition. Recently [Kolen M.ACS Omega2021, 6, 5698-5704], demonstrated a ∼3.5-fold increase in sensitivity by using a 1 mM concentration of the paramagnetic relaxation agent Gd. By combining our N decoupling technique with the relaxation agent Gd, we achieved a synergistic enhancement in sensitivity, resulting in an overall ∼10.9-fold sensitivity increase for the H NMR detection of NH . This translates to a reduction in NMR detection time by a factor of ∼119 (10.9). This significant advancement enables the fast detection of ammonia at μM concentration or lower. H NMR of NH with N decoupling was also demonstrated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11886909PMC
http://dx.doi.org/10.1021/acsomega.5c00337DOI Listing

Publication Analysis

Top Keywords

nmr detection
12
relaxation agent
12
nmr
8
nmr method
8
sensitivity
5
fast proton
4
proton nmr
4
detection
4
detection aqueous
4
ammonia
4

Similar Publications