A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Highly Sensitive Detection of Engrailed-2 Protein Biomarker in Urine for Using Solution-Gated Graphene Transistor Diagnosis of Prostate Cancer. | LitMetric

Highly Sensitive Detection of Engrailed-2 Protein Biomarker in Urine for Using Solution-Gated Graphene Transistor Diagnosis of Prostate Cancer.

ACS Sens

Key Laboratory for the Green Preparation and Application of Functional Materials, Ministry of Education, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Hubei Key Laboratory of Polymer Materials, College of New Energy and Electrica

Published: March 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Engrailed-2 (EN2) protein, a transcription factor in the homologous domain expressed in prostate cancer (PCa) cells and secreted into the urine, is considered a promising biomarker for noninvasive detection of PCa. EN2 protein in urine samples can be obtained by noninvasive means, but the low biomarker concentration in urine samples poses a great challenge for noninvasive detection of the PCa biomarker. Herein, we develop a solution-gated graphene transistor (SGGT) biosensor to detect the biomarker of the EN2 protein for PCa diagnosis. The aptamer probes are immobilized to the gold gate electrode through Au-S bonds. The effect of aptamer configurations on the biosensor's responses is also investigated. It can be found that the SGGT biosensor with the long-chain probes with a stem-like loop structure exhibits optimal performance. The limit of detection of biosensors can reach 0.1 fg/mL, and a rapid response time of 19 min is achieved. The SGGT biosensor also exhibits high specificity for the EN2 protein. More importantly, testing of clinical urine samples indicates that our sensor can distinguish PCa patients from non-PCa subjects. Compared to traditional hospital prostate-specific antigen tests, our sensor exhibits better accuracy for the noninvasive diagnosis of PCa.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.4c03320DOI Listing

Publication Analysis

Top Keywords

en2 protein
16
urine samples
12
sggt biosensor
12
solution-gated graphene
8
graphene transistor
8
prostate cancer
8
noninvasive detection
8
detection pca
8
pca
6
protein
5

Similar Publications