98%
921
2 minutes
20
Introduction: Shear wave elastography is a new modality for the evaluation of erectile dysfunction by assessing the stiffness of corpora cavernosal tissue. We evaluated the shear wave elastography values in erectile dysfunction participants and compared shear wave elastography values between vasculogenic and non-vasculogenic erectile dysfunction participants.
Methods: Overall, 40 participants with clinically diagnosed erectile dysfunction filled out an abridged five-item version of the international index of erectile dysfunction-5 questionnaire and underwent shear wave elastography as well as pharmacologically induced penile erection test after intracavernosal papaverine injection. Shear wave elastography values were obtained serially at 5-minute interval at two locations: Central (cavernosal artery centered circular region) and Peripheral (near the tunica albuginea). Shear wave elastography values were compared with the erectile dysfunction subtypes.
Results: Median international index of erectile dysfunction-5 score was 11 (interquartile range: 9-14). Median central shear wave elastography values were significantly lower in the erectile state as compared to flaccid state in both vasculogenic (8.27 kPa (interquartile range: 6.3-12.5) vs 23.27 kPa (interquartile range: 15.9-28.6) = 0.000) and non-vasculogenic (5.50 kPa (interquartile range: 4.4-6.7) vs 23.85 kPa (interquartile range: 17.8-33.6) = 0.000) erectile dysfunction participants. Vasculogenic erectile dysfunction participants had significantly higher central shear wave elastography value in erectile state than non-vasculogenic erectile dysfunction participants (8.27 kPa (interquartile range: 6.3-12.5) vs 5.50 kPa (interquartile range: 4.4-6.7) = 0.001). Receiver operating characteristics curve analysis revealed that the cut-off value for central shear wave elastography was 5.65 kPa in erectile state with the sensitivity, and specificity for predicting vasculogenic erectile dysfunction being 90.9% and 61.1%, respectively (area under the curve -0.816; standard error of 0.071 ( = 0.001)).
Conclusion: Central cavernosal shear wave elastography is a good modality to objectively quantify the penile rigidity and can be used to distinguish the subtype of ED.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11851578 | PMC |
http://dx.doi.org/10.1177/1742271X241275207 | DOI Listing |
PLoS One
September 2025
Mechanical and Nuclear Engineering Department, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates.
Sectionally nonlinearly functionally graded (SNFG) structures with triply periodic minimal surface (TPMS) are considered ideal for bone implants because they closely replicate the hierarchical, anisotropic, and porous architecture of natural bone. The smooth gradient in material distribution allows for optimal load transfer, reduced stress shielding, and enhanced bone ingrowth, while TPMS provides high mechanical strength-to-weight ratio and interconnected porosity for vascularization and tissue integration. Wherein, The SNFG structure contains sections with thickness that varies nonlinearly along their length in different patterns.
View Article and Find Full Text PDFZ Geburtshilfe Neonatol
September 2025
Department of Gynecology and Obstetrics, NMC Specialty Hospital Abu Dhabi, Abu Dhabi, United Arab Emirates.
The objective of this study was to assess the link between postpartum blood loss and placental elastography in multiparous pregnancies.In this prospective study, multiparous women who delivered at term between 2020 and 2024 were included. During the obstetric ultrasonography procedure, placental elastography was evaluated through the utilization of the shear wave elastography (SWE) technique.
View Article and Find Full Text PDFJ Biomech
September 2025
Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland. Electronic address:
Alterations in skeletal muscle morphology and composition are critical factors in cerebral palsy (CP), including changes in passive stiffness and in belly and fascicle lengths. In this study, we quantified the relative contributions of muscle and tendon to passive stiffness across the ankle range of motion in individuals with CP and typically developing (TD) peers. We also investigated morphological factors underlying increased muscle stiffness.
View Article and Find Full Text PDFTransplant Cell Ther
September 2025
Department of Medical Imaging, Hematology and Oncology, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
Background: Hepatic sinusoidal obstruction syndrome (SOS), or veno-occlusive disease (VOD), is a severe complication following hematopoietic stem cell transplantation (HSCT), often leading to liver dysfunction and poor outcomes if not detected early. Traditional diagnostic methods, including ultrasound and liver biopsy, have limitations in sensitivity and feasibility. Non-invasive elastography techniques, such as transient elastography (TE) and shear-wave elastography (SWE), offer a promising alternative by quantitatively assessing liver stiffness.
View Article and Find Full Text PDFHead Neck
September 2025
Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Zu Berlin, and Berlin Institute of Health, Berlin, Germany.
Background: Accurate preoperative differentiation of parotid gland tumors (PGTs) is essential for facial nerve preservation. This study evaluates a novel, real-time multiparametric ultrasound (mpUS) approach combining B-mode, shear wave elastography (SWE), and contrast-enhanced ultrasound (CEUS), based on qualitative image interpretation.
Methods: Eighty-nine patients with 91 PGTs underwent mpUS prior to surgery or ultrasound-guided biopsy.