AI-Assisted Passive Magnetic Distance/Position Sensor.

Sensors (Basel)

School of Information Science and Technology, Hangzhou Normal University, Hangzhou 311121, China.

Published: February 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Magnetic sensing technology is crucial for non-contact distance and position measurement. Due to the nonlinear characteristics of the magnetic fields from permanent magnets, conventional magnetic sensors struggle with accurate distance and position determination. To address this, we propose a distance/position sensor that employs a customized back propagation (BP) neural network. By detecting the magnetic field variations induced by a permanent magnet, the proposed sensor can effectively model the nonlinear mapping between magnetic field strength and distance, thereby enabling precise distance and position measurement. Experimental results demonstrate that the BP neural network approach, when employing a single magnetic sensor, exhibits a measurement error in the range of -0.0268 mm to 0.0362 mm over a distance of 0-70 mm, which is significantly lower than traditional methods based on the magnetic dipole model and the Levenberg-Marquardt (LM) algorithm. Increasing the number of sensors to three reduces the error further to -0.0107 mm to 0.0093 mm. Furthermore, when employing four magnetic sensors for position measurement within a 60 mm × 60 mm planar area, the positioning errors along the -axis and -axis are confined to the ranges of -0.6168 mm to 1.1312 mm and -0.6001 mm to 0.5133 mm, respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11858863PMC
http://dx.doi.org/10.3390/s25041132DOI Listing

Publication Analysis

Top Keywords

distance position
12
position measurement
12
magnetic
9
distance/position sensor
8
magnetic sensors
8
neural network
8
magnetic field
8
distance
5
ai-assisted passive
4
passive magnetic
4

Similar Publications

Background: Labeo fimbriatus (Bloch, 1795) is a medium-sized South Asian minor carp with ecological significance and emerging aquaculture potential, particularly in polyculture systems with Indian major carps. Despite its wide distribution, it remains underrepresented in phylogenetic studies, and limited genomic resources are available. Here, we report the complete mitochondrial genome sequence of L.

View Article and Find Full Text PDF

Diversity-Oriented C-H Activation Reactions of the Naphthalene Scaffold.

J Am Chem Soc

September 2025

Department of Chemistry, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, California 92037, United States.

Diversity-oriented synthesis (DOS) has emerged as an efficient strategy for constructing diverse compound libraries, facilitating hit or lead identification in the drug discovery process. In parallel, developing diverse transformations at different sites is an appealing strategy to expand the diversity of appendages on scaffolds. Owing to the availability of C-H bonds at multiple sites of pharmacophores, diversity-oriented C-H activation reactions are an ideal approach to realize this goal.

View Article and Find Full Text PDF

Background Sacroiliac joint fusion is performed to stabilize and fuse the joint in patients with degenerative sacroiliitis and joint dysfunction. While several posterior techniques and implants exist as alternatives to lateral approaches, biomechanical and clinical performance data for these systems used as standalone remains limited. This article provides a preliminary cadaveric and clinical assessment of a novel posterior intra-articular sacroiliac fusion implant system.

View Article and Find Full Text PDF

Intraocular repair for subluxation of a multifocal intraocular lens (MFIOL) can be challenging, especially in toric models. Herein, we report a case of a 43-year-old man with a subluxated toric-type single-piece trifocal intraocular lens (IOL) with a C-loop that was spared using suture repositioning. Pars plana suturing was performed using the haptic externalization technique, and the tram-track suture technique was employed to flatten the tilted toric MFIOL.

View Article and Find Full Text PDF

Background: This study aimed to evaluate how subscapularis tendon repair influences joint loads in relation to humeral offset and arm position.

Patients And Methods: Two fresh-frozen, whole-body cadaveric shoulders underwent a reverse total shoulder arthroplasty (rTSA) on the humeral side using an internal proprietary load-sensing system (LSS) (Goldilocks, Statera Medical, Montreal, Canada). In addition to three "complex" Activity Daily Life positions ("behind the back", "overhead reach", and "across the chest"), four standard postures (external rotation, extension, abduction, and flexion) were used to record the glenohumeral loads (Newtons) and their locations applied to the implant.

View Article and Find Full Text PDF