A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta-Analysis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: We conducted a systematic review and meta-analysis to compare venous couplers and hand-sewn techniques for venous anastomosis in head and neck reconstruction.

Data Sources: PubMed/MEDLINE and Scopus, databases were searched for relevant publications. Additionally, a manual search was performed in Google Scholar and through reference lists.

Review Methods: Retrospective and prospective cohort studies were included. Odds ratios (ORs) and mean differences (MD) were calculated with their 95% confidence intervals (CIs) for each study comparing the 2 groups (coupler vs hand). The inverse variance method was used to combine the effect sizes from the individual studies.

Results: A total of 14,053 patients undergoing 14,270 head and neck free flap reconstructions were included from 52 studies. A total of 6080 flaps were performed using a coupling device for the venous anastomoses, while 8190 flaps were performed with the hand-sewn technique. No significant difference was found for the venous thrombosis rate (OR: 1.06, 95% CI: 0.65-1.72), and reoperation rate (OR: 0.93, 95% CI: 0.51-1.70), but a significantly lower failure rate was measured for the coupler group (OR = 0.34, 95% CI: 0.20-0.58). A nonsignificant lower operative time was found for venous anastomoses (MD: -20.5, 95% CI: -51.7 to 10.7) and total surgery (MD: -23.7, 95% CI: -344.3 to 296.8) for the coupler group.

Conclusion: Despite the slight advantages observed with venous couplers, the overall outcomes of both techniques are excellent, and the choice of anastomotic technique should be guided by surgeon preference.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ohn.1167DOI Listing

Publication Analysis

Top Keywords

venous anastomoses
12
head neck
12
systematic review
8
review meta-analysis
8
venous couplers
8
flaps performed
8
venous
7
95%
6
microvascular coupling
4
coupling venous
4

Similar Publications