A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Rapid simultaneous quantification of arsenic and lead in grain using improved monochromatic excitation energy dispersive X-ray fluorescence spectrometry. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In most cases, conventional energy dispersive X-ray fluorescence (EDXRF) analysis of trace arsenic (As) and lead (Pb) in grains encounters technical difficulties due to sensitivity challenges and the overlapping of characteristic X-ray lines. By utilizing high-definition X-ray technology and doubly curved crystal (DCC), along with establishing interference correction models for As and Pb, we can significantly improve analytical sensitivity for specific portions of the spectrum while reducing interference. This study demonstrates that the improved monochromatic excitation energy dispersive X-ray fluorescence spectrometry (MEDXRF), combined with an algorithmic analysis of fundamental parameters (FP), exhibits higher sensitivity compared to existing EDXRF methods. This improvement is achieved by optimizing the DCC structure, device geometry layout, and detection conditions. The detection limits, precision, and accuracy of MEDXRF for As and Pb were evaluated using certified reference materials (CRMs) and actual grain samples. The test results indicate that the limits of detection (LODs) were generally better than those specified by the Codex general standard, with values of 0.02 mg/kg for As and 0.03 mg/kg for Pb. The accuracy and precision were in good agreement with ICP-MS results. Therefore, the enhanced MEDXRF method offers sufficient sensitivity, accuracy and stability for the direct determination of As and Pb in grains below food safety limits.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2025.127719DOI Listing

Publication Analysis

Top Keywords

energy dispersive
12
dispersive x-ray
12
x-ray fluorescence
12
arsenic lead
8
improved monochromatic
8
monochromatic excitation
8
excitation energy
8
fluorescence spectrometry
8
x-ray
5
rapid simultaneous
4

Similar Publications