Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Imaging flow cytometry (IFC) combines the imaging capabilities of microscopy with the high throughput of flow cytometry, offering a promising solution for high-precision and high-throughput cell analysis in fields such as biomedicine, green energy, and environmental monitoring. However, due to limitations in imaging framerate and real-time data processing, the real-time throughput of existing IFC systems has been restricted to approximately 1000-10,000 events per second (eps), which is insufficient for large-scale cell analysis. In this work, we demonstrate IFC with real-time throughput exceeding 1,000,000 eps by integrating optical time-stretch (OTS) imaging, microfluidic-based cell manipulation, and online image processing. Cells flowing at speeds up to 15 m/s are clearly imaged with a spatial resolution of 780 nm, and images of each individual cell are captured, stored, and analyzed. The capabilities and performance of our system are validated through the identification of malignancies in clinical colorectal samples. This work sets a new record for throughput in imaging flow cytometry, and we believe it has the potential to revolutionize cell analysis by enabling highly efficient, accurate, and intelligent measurement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11808109 | PMC |
http://dx.doi.org/10.1038/s41377-025-01754-9 | DOI Listing |