A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Specific molecular imaging of BALB/c model mice with Graves' ophthalmopathy based on high expression of insulin-like growth factor 1 receptor. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: At present, most of the targeted imaging based on insulin-like growth factor 1 receptor (IGF-1R) is for tumor research, and there is no IGF-1R-targeted imaging for Graves' ophthalmopathy(GO). This study aims to develop a peptide probe, Tc-Z-GGGC, targeting the IGF-1R, and to achieve specific imaging in Graves' disease (GD) animal models exhibiting GO.

Methods: 99mTc-ZIGF1R:4551-GGGC probe was synthesized using a direct labeling method and its labeling efficiency assessed via instant thin-layer chromatography (ITLC). Western blot analysis confirmed the overexpression of IGF-1R in malignant melanoma B16F10 cells. Subsequent SPECT/CT whole-body imaging of B16F10 tumor-bearing mice evaluated the probe's targeting accuracy. In addition, a GO model was established using an electroporation immunoassay, followed by serological and histopathological examinations. The GO models then underwent 99mTc-ZIGF1R:4551-GGGC SPECT/CT imaging to assess eye-targeted imaging capabilities.

Results: The peptide probe exhibited a labeling efficiency exceeding 90%. Both GD and GO models were effectively created via electroporation immunoassay. Imaging results indicated significant accumulation and retention of the peptide probes in the tumors of B16F10 tumor-bearing mice. In the GO models, probe uptake was predominantly observed in retrobulbar tissues, contrasting with primary accumulation in the lungs and gastrointestinal tract in normal mice, where only minimal tracer was observed in retrobulbar tissues. Notably, GO mice demonstrated higher probe uptake and prolonged retention.

Conclusion: This study successfully established GD and GO models, reducing the duration of the immune cycle. Moreover, a peptide probe targeting IGF-1R was synthesized, enabling specific imaging of retrobulbar tissues in GO models.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11914231PMC
http://dx.doi.org/10.1007/s12149-024-02013-4DOI Listing

Publication Analysis

Top Keywords

peptide probe
12
retrobulbar tissues
12
imaging
9
insulin-like growth
8
growth factor
8
factor receptor
8
imaging graves'
8
targeting igf-1r
8
specific imaging
8
labeling efficiency
8

Similar Publications