Enhancing heart and circulatory well-being through optimized radial artery techniques: a meta-analysis of hemostasis and patient comfort.

Front Cardiovasc Med

Department of Cardiovascular Medicine, Capital Medical University, Beijing LuHe Hospital, Beijing, China.

Published: January 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: This meta-analysis elucidates the efficacy of the Transradial Band Device (TR Band) in minimizing complications like radial artery occlusion and hematoma, preserving heart health, and enhancing blood flow post-transradial catheterization.

Methods: A comprehensive literature search across databases including PubMed, Cochrane, and Embase examined the impact of radial artery compression techniques and decompression times on complications. Data from 13 studies were analyzed using R 4.1.2 with fixed-effects and random-effects models. The Newcastle-Ottawa Scale assessed the risk of bias in observational cohort studies.

Results: In our meta-analysis, we evaluated data from various studies encompassing different air volumes in transradial band devices across several outcomes including bleeding, hematoma, radial artery occlusion (RAO), Visual Analog Scale (VAS) scores, and compression time. The collective analysis integrated findings from 11 studies, totaling 4,679 patients. No significant difference in bleeding risk (OR 1.04, 95% CI 0.60-1.82,  > 0.05,  = 78%), hematoma incidence (OR 0.96, 95% CI 0.78-1.19,  > 0.05,  = 0%), or RAO incidence (OR 0.96, 95% CI 0.78-1.19,  > 0.05,  = 0%) was observed between the "Less air" and "15 ml air" groups. However, the "Less air" group reported significantly higher VAS scores indicating increased pain or discomfort (Mean Difference 0.25, 95% CI 0.09-0.41,  < 0.05,  = 0%). Compression time analyses showed no significant difference between groups (Mean Difference -17.73, 95% CI -54.65-19.20,  > 0.05,  = 99%). Sensitivity analyses confirmed the stability of these findings, and Egger's test indicated no significant publication bias across the outcomes. This synthesis highlights the nuanced impact of air volume adjustments in transradial bands on patient outcomes, emphasizing the necessity for further research and standardized protocols to optimize patient safety and comfort post-intervention.

Conclusion: The TR Band, when utilized with optimized air volume/pressure, maintains an essential balance between ensuring hemostasis and enhancing patient comfort without elevating the risk of radial artery complications. These findings support the careful selection of TR Band settings to optimize clinical outcomes in patients undergoing transradial cardiac procedures. Further research is warranted to establish standardized guidelines for the most effective use of TR Band in various clinical scenarios.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11776028PMC
http://dx.doi.org/10.3389/fcvm.2024.1412479DOI Listing

Publication Analysis

Top Keywords

radial artery
20
patient comfort
8
transradial band
8
artery occlusion
8
data studies
8
vas scores
8
incidence 096
8
096 95%
8
95% 078-119
8
078-119  > 005
8

Similar Publications

Some patients with heart failure with preserved ejection fraction (HFpEF) have demonstrated evidence of exercise-induced arterial hypoxaemia (EIAH). However, EIAH was not quantified using , , and measurements as previously conducted in healthy adults nor was EIAH quantified alongside simultaneous measurements of pulmonary vascular pressures, cardiorespiratory responses, or dyspnoea on exertion (DOE) in these patients. Given the effects of hypoxaemia on pulmonary vasoconstriction, cardiorespiratory responses, and DOE, we tested the hypothesis that patients with HFpEF and EIAH (EIAH) would demonstrate higher pulmonary vascular pressures, worse oxygen uptake, and greater DOE compared with patients without EIAH (EIAH).

View Article and Find Full Text PDF

Background: Radial artery avulsion (RAV) is a rare but potentially serious complication of transradial angiographic procedures.

Case Summary: We describe a 70-year-old man who presented with atypical chest discomfort and who underwent cardiac catheterization from the right radial artery. The patient had radial artery spasm, and a piece of tissue approximately 6 cm in length was pulled out of the sheath.

View Article and Find Full Text PDF

The transradial approach (TRA) is gaining popularity in neuroendovascular therapy due to its safety and patient comfort, but its application in emergency settings with complex vascular anatomy remains technically demanding. This study assessed the feasibility and safety of using the 6 Fr FUBUKI XF long guiding sheath-a non-radial-specific device-for neuroendovascular procedures via TRA. Nineteen consecutive patients treated with the FUBUKI XF long guiding sheath between April 2024 and June 2025 were retrospectively reviewed and compared with a small cohort treated using the radial-specific Rist guiding sheath during the same period.

View Article and Find Full Text PDF

Purpose: Although transradial arterial access has been increasingly used in neurointerventional procedures, anatomical variations, vasospasm, or radial artery occlusion can preclude safe access to the radial artery. This study evaluates the feasibility and safety of transulnar artery access as an alternative route for diagnostic cerebral angiography and neurovascular interventions.

Materials And Methods: A retrospective review was conducted at a high-volume academic neurovascular center.

View Article and Find Full Text PDF

Impact of obesity on palpation-guided distal radial access for coronary procedures: subgroup analysis of the multicenter, prospective KODRA registry.

Cardiol J

September 2025

Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine and Cardiovascular Center, Yongin Severance Hospital, Yongin, Republic of Korea.

Background: There is limited data on the impact of body mass index (BMI) on distal radial access (DRA). Using a large-scale prospective registry, the influence of obesity on DRA outcomes was evaluated, including cannulation and complications.

Methods: Using data from the prospective, multicenter KODRA (Korean Prospective Registry for Evaluation the Safety and Efficacy of Distal Radial Approach) registry data, 4,638 patients who planned palpation-guided distal radial artery puncture were enrolled into two groups, both with body mass index (BMI) information available: obese (n = 2,205; BMI ≥ 25 kg/m²) and non-obese (n = 2,433).

View Article and Find Full Text PDF