Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose To assess the effect of scanner manufacturer and scanning protocol on the performance of deep learning models to classify aggressiveness of prostate cancer (PCa) at biparametric MRI (bpMRI). Materials and Methods In this retrospective study, 5478 cases from ProstateNet, a PCa bpMRI dataset with examinations from 13 centers, were used to develop five deep learning (DL) models to predict PCa aggressiveness with minimal lesion information and test how using data from different subgroups-scanner manufacturers and endorectal coil (ERC) use (Siemens, Philips, GE with and without ERC, and the full dataset)-affects model performance. Performance was assessed using the area under the receiver operating characteristic curve (AUC). The effect of clinical features (age, prostate-specific antigen level, Prostate Imaging Reporting and Data System score) on model performance was also evaluated. Results DL models were trained on 4328 bpMRI cases, and the best model achieved an AUC of 0.73 when trained and tested using data from all manufacturers. Held-out test set performance was higher when models trained with data from a manufacturer were tested on the same manufacturer (within- and between-manufacturer AUC differences of 0.05 on average, < .001). The addition of clinical features did not improve performance ( = .24). Learning curve analyses showed that performance remained stable as training data increased. Analysis of DL features showed that scanner manufacturer and scanning protocol heavily influenced feature distributions. Conclusion In automated classification of PCa aggressiveness using bpMRI data, scanner manufacturer and ERC use had a major effect on DL model performance and features. Convolutional Neural Network (CNN), Computer-aided Diagnosis (CAD), Computer Applications-General (Informatics), Oncology Published under a CC BY 4.0 license. See also commentary by Suri and Hsu in this issue.

Download full-text PDF

Source
http://dx.doi.org/10.1148/ryai.230555DOI Listing

Publication Analysis

Top Keywords

scanner manufacturer
16
model performance
12
endorectal coil
8
prostate cancer
8
manufacturer scanning
8
scanning protocol
8
performance
8
deep learning
8
learning models
8
pca aggressiveness
8

Similar Publications

In-line multi-wavelength non-destructive pharma quality monitoring with ultrabroadband carbon nanotubes photo-thermoelectric imaging scanners.

Light Sci Appl

September 2025

Department of Electrical, Electronic, and Communication Engineering, Faculty of Science and Engineering, Chuo University, 1-13-27 Kasuga, Bunkyo-ku, Tokyo, 112-8551, Japan.

While non-destructive in-line monitoring at manufacturing sites is essential for safe distribution cycles of pharmaceuticals, efforts are still insufficient to develop analytical systems for detailed dynamic visualisation of foreign substances and material composition in target pills. Although spectroscopies, expected towards pharma testing, have faced technical challenges in in-line setups for bulky equipment housing, this work demonstrates compact dynamic photo-monitoring systems by selectively extracting informative irradiation-wavelengths from comprehensive optical references of target pills. This work develops a non-destructive in-line dynamic inspection system for pharma agent pills with carbon nanotube (CNT) photo-thermoelectric imagers and the associated ultrabroadband sub-terahertz (THz)-infrared (IR) multi-wavelength monitoring.

View Article and Find Full Text PDF

Purpose: This in vitro study evaluated the adaptation and fracture resistance of screw- and cement-retained implant-supported restorations using lithium disilicate crowns cemented onto titanium bases and universal abutments of different heights.

Methods: Thirty crowns were designed, milled, and divided into three groups: TBA (titanium base abutment - 4.7-mm-height and 4.

View Article and Find Full Text PDF

Adolescent neuroimaging studies of sex differences in the human brain predominantly examine average differences between males and females. This focus on mean differences without probing relative distributions and similarities may contribute to both conflation and overestimation of sex differences and sexual dimorphism in the developing human brain. We aimed to characterize the variance in brain macro- and micro-structure in early adolescence as it pertains to sex at birth using a large sample of 9-11-year-olds from the Adolescent Brain Cognitive Development (ABCD) Study (N = 7,723).

View Article and Find Full Text PDF

Background: To guarantee high-quality patient scans, thorough quality assurance (QA) of SPECT or gamma cameras, including performance, review, and documentation, is essential.

Purpose: We developed a novel Nuclear Medicine Quality Assurance server (NMQA) with an AI deep learning (AIDL) optical character recognition (OCR) system to automate QA data retrieval and review from SPECT and gamma cameras. The system extracts and compares daily and weekly QA data against specifications.

View Article and Find Full Text PDF

A vendor-neutral MR bone imaging technique based on 3D time-of-flight MR angiography with spoiled gradient recalled acquisition in the steady state (TOF-SPGR) was developed to enhance the depiction of bone and calcification/ossification. This approach is independent of scanner manufacturer and application type, enabling reduced radiation exposure by replacing or triaging further CT examinations. This article describes the optimization of scan parameters for clinical musculoskeletal protocols and explores its clinical applications with representative cases.

View Article and Find Full Text PDF