A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT. | LitMetric

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. E

Published: February 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT. Images were acquired with fast pitch and full spectral capabilities (collimation 144 × 0.4 mm). The contrast protocol included a mixture of sodium chloride and iodinated contrast agent (Iopromide, total iodine dose: 9.5-9.8 g). Virtual monoenergetic images (VMIs) were reconstructed at 40, 50, 60, and 68 keV. Two blinded radiologists evaluated image quality on a 4-point scale. Attenuation was measured across eight regions in the aorta and iliac arteries, and contrast-to-noise ratio (CNR) was calculated. Statistical comparisons were performed using repeated measures ANOVA and Bonferroni post-hoc tests.

Results: The final cohort consisted of 39 subjects (mean age: 69.6 ± 9.6 years; 30.8 % female). VMI at 40 keV provided significantly higher attenuation: 478 ± 114 HU, compared to 50 keV (331 ± 74 HU), 60 keV (241 ± 51 HU), and 68 keV (190 ± 48 HU) (p < 0.01). This translated in increased CNR for 40 keV reconstructions (11.8 ± 3.9), followed by 50 keV (9.1 ± 3.0), 60 keV (7.0 ± 2.3), and 68 keV (6.1 ± 1.9) (p < 0.01). Subjective image quality was rated excellent at 40 keV (4 [3,4]), though associated with highest noise (38 ± 7.4 HU, p = 0.02).

Conclusion: Aortoiliac CTA using dual-source PCD-CT at 40 keV achieved high attenuation and CNR, enabling effective imaging with only 9.8 g of iodine.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2025.111919DOI Listing