The effect of the guide hole height on the accuracy of implant placement: An in-vitro study.

J Stomatol Oral Maxillofac Surg

School of Dentistry, Chonnam National University, Gwangju, Republic of Korea; Department of Oral & Maxillofacial Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea. Electronic address:

Published: September 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Guided implant surgery using three-dimensional (3-D) planning software and 3-D printed surgical guides has become a critical tool for enhancing accuracy. This study aims to determine the minimum guide hole height necessary to maintain implant placement accuracy.

Materials And Methods: Ten maxillary models with edentulous areas were created using CT and optical scan data. Six sites (for each model) were prepared for implant placement with surgical guides fabricated using a 3-D printer. Sixty implants were placed using these guides and divided into five groups according to the guide hole height (1 to 5 mm). After the placement, digital impressions were taken to assess the accuracy of implant positioning. Deviations between planned and actual implant positions were investigated using computer software, and data were statistically analyzed using ANOVA and Kruskal-Wallis tests.

Results: Guide holes with 1 mm height (Group Ⅰ) resulted in the highest 3-D deviations (1.12 ± 0.36 and 1.99 ± 0.74 mm at the coronal and apical positions, respectively), with significant errors at the implant apical position compared to groups with taller guide holes (Groups Ⅳ and Ⅴ) (p = 0.005). There were no significant deviations between the 3 mm and 5 mm guide hole heights, with no statistical differences between groups at the x, y, and z-axis in the implant position.

Conclusion: A comparison between the group with a guide hole height of 5 mm on one side and the group with a height of 1 mm on both sides revealed a significant difference in implant placement accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jormas.2025.102232DOI Listing

Publication Analysis

Top Keywords

guide hole
20
hole height
16
implant placement
16
implant
9
accuracy implant
8
surgical guides
8
guide holes
8
guide
7
height
6
placement
5

Similar Publications

Purpose: Crown preparation is a fundamental procedure in restorative dentistry. This study aimed to evaluate quantitative and color-coded assessment of tooth reduction using various 3D-printed tooth reduction guides in comparison to conventional guiding methods during crown preparation.

Methods: Twelve prosthodontic residents from a single prosthodontic graduate program (first year: n = 6; second year: n = 6) participated in this IRB-approved study (Yonsei University Dental Hospital IRB 2-2024-0026).

View Article and Find Full Text PDF

Objective: To determine if a novel robotic system has comparable positional and angular accuracy to that achievable with patient-specific guides (PSG) when used for transcondylar screw (TCS) placement in the canine humerus.

Study Design: Experimental laboratory study.

Sample Population: A total of 32 synthetic humeral models (16 per group).

View Article and Find Full Text PDF

Background: Cancer morbidity disproportionately affects patients in low- and middle-income countries (LMICs), where timely and accurate tumor profiling is often nonexistent. Immunohistochemistry-based assessment of estrogen receptor (ER) status, a critical step to guide use of endocrine therapy (ET) in breast cancer, is often delayed or unavailable. As a result, ET is often prescribed empirically, leading to ineffective and toxic treatment for ER-negative patients.

View Article and Find Full Text PDF

Objective: The recently emerging laser interstitial thermal therapy is becoming a substitute treatment for mesial temporal lobe epilepsy (MTLE) due to its less invasiveness, but it offers lower seizure-free rates than traditional open surgery. Another less invasive stereotactic ablation surgery, that is radiofrequency thermocoagulation, is also an alternative surgical procedure. In particular, magnetic resonance imaging-guided stereotactic radiofrequency thermocoagulation (MRgSRFTC) has shown excellent seizure outcomes.

View Article and Find Full Text PDF

This study explored a novel digital design and fabrication method for a double constrained split orthodontic miniscrew guide to improve the accuracy and safety of clinical miniscrew implantation and reduce related complications. A patient requiring miniscrew implantation was selected, and data were acquired using cone beam computed tomography (CBCT) and intraoral optical scanning. For the construction of a double constrained split guide including a screw-hole guide and an insertion rod guide, different types of software such as Mimics 24.

View Article and Find Full Text PDF