Article Abstract

Objectives: Our study aimed to compare signal characteristics of subdural electrodes (SDE) and depth stereo EEG placed within a 5-mm vicinity in patients with drug-resistant epilepsy. We report how electrode design and placement collectively affect signal content from a shared source between these electrode types.

Methods: In subjects undergoing invasive intracranial EEG evaluation at a surgical epilepsy center from 2012 to 2018, stereo EEG and SDE electrode contacts placed within a 5-mm vicinity were identified. Of these, 24 contacts (12 pairs) met our criteria for signal-to-noise ratio and data availability for final analysis. We used Welch method to analyze the correlation of power spectral densities of EEG segments, root mean square of 1-second windows, and fast-Fourier transform to calculate coherence across conventional frequency bands.

Results: We observed a median distance of 3.7 mm between the electrode contact pairs. Time-aware analysis highlighted the coherence's strength primarily in the high-gamma band, where the median ( r ) was 0.889. In addition, the median power ratios between the SDE and stereo EEG signal was 1.99. This ratio decreased from high-gamma to infra-low frequencies, with medians of 2.07 and 0.97, respectively. The power spectral densities for the stereo EEG and SDE electrodes demonstrated a strong correlation, with a median correlation coefficient ( r ) of 0.99 and an interquartile range from 0.915 to 0.996.

Conclusions: Signals captured by standard subdural and depth (intracranial EEG) electrodes within a 5-mm radius exhibit band-specific coherence and are not identical. The association was most pronounced in the high-gamma band, with coherence decreasing with lower frequencies. Our findings underscore the combined effects of electrode size, design, placement, preferred bandwidth, and the nature of the activity source on signal recording. Particularly, SDE employed herein may offer advantages for high-frequency signals, but the impact of electrode size on recordings necessitates careful consideration in context-specific situations.

Significance: The findings relate to surgical epilepsy care and may inform the design of brain-computer interface.

Download full-text PDF

Source
http://dx.doi.org/10.1097/WNP.0000000000001139DOI Listing

Publication Analysis

Top Keywords

stereo eeg
16
eeg signal
8
signal characteristics
8
characteristics subdural
8
subdural depth
8
5-mm vicinity
8
design placement
8
intracranial eeg
8
surgical epilepsy
8
eeg sde
8

Similar Publications

Experiential reflex epilepsy demonstrated with stereoEEG.

Seizure

August 2025

Danish Epilepsy Centre Filadelfia, Dianalund, Denmark; Postgraduation Programme in Clinical Medicine, Federal University of Santa Catarina, Florianópolis, SC, Brazil; Vilnius University, Faculty of Medicine, Institute of Clinical Medicine, Clinic of Neurology and Neurosurgery, Lithuania.

Purpose: Reflex epilepsies are epileptic disorders in which seizures are consistently provoked by specific, identifiable stimuli-typically sensory or cognitive. In patients with memory-induced seizures, it has long been debated whether the memory acts as the trigger for the seizure or represents its first clinical manifestation.

Methods: We present the case of a 25-year-old woman with reflex seizures triggered by the recollection of specific autobiographical memories.

View Article and Find Full Text PDF

Speech brain-computer interfaces (BCIs) offer a solution for those affected by speech impairments by decoding brain activity into speech. Current neuroprosthetics focus on the motor cortex, which might not be suitable for all patient populations. We investigate potential alternative targets for a speech BCI across a brain-wide distribution.

View Article and Find Full Text PDF

A critical review of high-frequency activity for functional mapping in SEEG.

Epilepsia

September 2025

Department of Neuroscience, The School of Translational Medicine, Monash University, Melbourne, Victoria, Australia.

Mapping functional brain networks is a critical component of stereo-electroencephalography (SEEG) evaluations. Although direct cortical stimulation (DCS) is the clinical gold standard, it has important limitations-particularly in mapping distributed, complex functions such as language and memory, where deficits may still occur despite preservation of DCS-positive sites, impacting quality of life. More broadly, there is increasing emphasis on preserving cognitive function in epilepsy surgery.

View Article and Find Full Text PDF

Leveraging Functional and Structural Connectomics to Guide Neuromodulation in Epilepsy.

J Clin Neurophysiol

July 2025

The Cortical Systems and Neural Engineering Laboratories, Department of Neurosurgery and Rehabilitation, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A.

Epilepsy is not solely a disorder of abnormal brain structure; it is fundamentally a disorder of disrupted brain networks and impaired communication across brain regions. Thalamic neuromodulation, once conceptualized as a fixed, anatomically guided intervention, is now undergoing a paradigm shift toward dynamic, network-informed modulation. Using tools such as stereo-EEG, diffusion MRI, and advanced connectomic analyses, we are entering a new era where neurostimulation strategies can be individualized, responsive, and aligned with the real-time neurophysiology and structural networks of each patient.

View Article and Find Full Text PDF

The data obtained from stereo-elecroencephalography (SEEG) in patients with focal epilepsy are crucial for defining the epileptogenic zone and achieving successful resection, but suboptimal electrode placement impairs SEEG results. We demonstrate an approach for concurrent scalp and depth EEG analysis from one patient with successful intracranial workup and one in whom the seizure onset zone was unsampled by SEEG. Intracranial epileptiform discharges were identified and clustered, their scalp correlates were averaged, and electric source imaging (ESI) was applied to the resulting averaged scalp potential - depth-to-scalp ESI (dsESI).

View Article and Find Full Text PDF