Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
To determine the feasibility of implementing Ovarian-Adnexal Reporting & Data System (O-RADS) ultrasound (US) for reporting of adnexal masses at our institution, with a specific goal of increasing the use of O-RADS from a baseline of <5% to at least 75% over a 16-month period. A prospective interrupted time series quality improvement study was undertaken over a 16-month period. Plan, do, study, act cycles included: (1) Engagement of interested parties, (2) Targeted educational sessions, (3) Development of reporting templates, (4) Weekly audit-feedback. Inter-reader variability assessment was performed on 70% of O-RADS risk-category 2 to 5. The primary outcome was the reporting of an O-RADS risk category. A total of 635 female pelvic US were performed at our centre between July 2022 and April 2023. An O-RADS risk category was provided on the final radiology report by the radiologist for 489/635 (77%) US. From November 2022 to April 2023, the weekly rate of O-RADS risk category reporting reached 88%. The O-RADS score was concordant between readers for 83/103 (81%) of US reports with kappa score of 0.69 corresponding to good agreement. The reporting of O-RADS risk category increased from <5% to 88% over a 16-month period with a high level of agreement among readers in assigning O-RADS risk category. Implementation of a standardizing reporting ultrasound system at a tertiary cancer centre is feasible with rapid learning and uptake curves.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/08465371241301335 | DOI Listing |