Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Pancreatic cystic lesions (PCLs) are frequently detected incidentally and vary from benign to malignant. Accurate differentiation between mucinous (M-PCLs) and non-mucinous PCLs (NM-PCLs) is essential for appropriate management. This study aims to validate the accuracy of on-site glucose measurement using a glucometer with a cut-off of 50 mg/dL for distinguishing M-PCLs from NM-PCLs.
Methods: In this prospective multicenter study, conducted at three European academic hospitals, patients who underwent endoscopic ultrasound-guided fine-needle aspiration for PCLs between 2019 and 2020 were included. On-site glucose measurement was performed using a conventional glucometer. Data on demographics, clinical features, EUS findings, and histopathology were collected.
Results: Fifty patients were enrolled, with 37 having glucose levels < 50 mg/dL and 13 ≥ 50 mg/dL. M-PCLs were more common in the <50 mg/dL group (81%) compared to the ≥50 mg/dL group (23%, < 0.001). The median CEA was higher in the <50 mg/dL group (146 ng/mL) than in the ≥50 mg/dL group (3 ng/mL, = 0.047). On-site glucose testing < 50 mg/dl demonstrated a sensitivity of 93.2%, a specificity of 76.5%, and an accuracy of 89% for detecting M-PCLs with an AUC of 0.74 and an OR of 14.29 ( < 0.001). In comparison, CEA > 192 ng/mL had a sensitivity of 55.6%, a specificity of 87.5%, and an accuracy of 75.8% for M-PCLs, with an AUC of 0.65 and an OR of 4.44.
Conclusions: On-site glucose measurement using a glucometer with a cut-off of <50 mg/dL is a highly accurate, rapid, and cost-effective method for differentiating M-PCLs from NM-PCLs. Our results validate the glucose cut-off in a multicentric prospective cohort supporting its integration into standard diagnostic protocols for PCLs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11674768 | PMC |
http://dx.doi.org/10.3390/cancers16244198 | DOI Listing |