Article Abstract

We present a case of an adult patient with a large symptomatic fusiform basilar artery aneurysm. This video demonstrates the ease of deploying the new Pipeline™ Vantage Flow Diverter compared to the Flex model in the same vessel. The Flex and Vantage have different deployment techniques-as using the Flex maneuvering technique on the Vantage may damage the braid. The Vantage stent does not require resheathing, dragging, or system loading. The video shows the operator's hands making multiple adjustments to deploy the Flex, while they deploy two Vantage stents and a LOBO device occluder before fully deploying the Flex. The Vantage appears to offer a simpler, more streamlined deployment process of mostly unsheathing compared to the Flex flow diverter. Also, the Vantage design might offer a higher aneurysmal occlusion rate with a shorter course of anti-platelet regimen. Of note, the Pipeline™ Shield may be a more appropriate option in some cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11780492PMC
http://dx.doi.org/10.1177/15910199241311074DOI Listing

Publication Analysis

Top Keywords

flex vantage
12
fusiform basilar
8
basilar artery
8
artery aneurysm
8
flow diverter
8
compared flex
8
flex
7
vantage
7
vantage pipeline™
4
pipeline™ flow
4

Similar Publications

Background And Purpose: Unruptured intracranial aneurysms (IA) are pathologic bulging of the arterial walls that could rupture and cause SAH. Recently, stents with modified surfaces have been used as treatment for IA. Thus, comparing efficacy and security of the Pipeline Flex Embolization Device with Shield Technology (PED-Shield) and the Pipeline Vantage Embolization Device with Shield Technology (PEDV) contributes to the scientific literature.

View Article and Find Full Text PDF

We present a case of an adult patient with a large symptomatic fusiform basilar artery aneurysm. This video demonstrates the ease of deploying the new Pipeline™ Vantage Flow Diverter compared to the Flex model in the same vessel. The Flex and Vantage have different deployment techniques-as using the Flex maneuvering technique on the Vantage may damage the braid.

View Article and Find Full Text PDF

Objective: To provide a video tutorial on the diagnostic ultrasound approach to the medial compartment of the canine shoulder and provide comparisons of normal and pathological images with corresponding MRI.

Animals: Dogs undergoing diagnostic ultrasound of the medial shoulder.

Methods: The medial shoulder was positioned in flexion with external rotation to allow transducer access, clipped, and scrubbed with dilute chlorhexidine.

View Article and Find Full Text PDF
Article Synopsis
  • This study analyzed the safety and effectiveness of coated flow diverters (cFDs) for treating cerebral aneurysms while patients were on single antiplatelet therapy (SAPT).
  • It involved 41 patients with a median age of 58, noting a low complication rate with only 5% experiencing early ischemic issues, and no complications reported after four months for most patients.
  • The results suggest that using cFDs under SAPT shows a promising occlusion rate (75% complete, 89% favorable) and calls for further research through prospective trials.
View Article and Find Full Text PDF

Multicenter Experience with the Pipeline Flex and Vantage with Shield Technology for Intracranial Aneurysm Treatment.

AJNR Am J Neuroradiol

October 2024

From the Department of Radiology and Neuroradiology (L.G., D.Z., L.P., J.K., M.S., C.K.), University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany.

Background And Purpose: The Pipeline Embolization Device is a safe and effective treatment option for intracranial aneurysms. The newer Pipeline generations have received structural refinements and a surface modification to improve deliverability, procedural safety, and angiographic outcomes. This multicenter study evaluated the clinical safety and efficacy of the 2 surface-modified Pipeline iterations, Pipeline Vantage and Pipeline Flex with Shield Technology (PFS).

View Article and Find Full Text PDF