98%
921
2 minutes
20
PDA stenting is increasingly utilized for patients with ductal-dependent pulmonary blood flow. Predicting optimal stent length prior to and during the intervention remains a challenge. The utility of pre-catheterization computed tomography angiography (CTA) to predict stent length was evaluated. All patients that received a PDA stent for pulmonary blood flow between 2019 and 2022 with a pre-stent CTA were reviewed. Several CTA and catheter angiography-based measurements of the native and stented PDA were performed. Curvilinear and straight-line PDA lengths were determined by pre-catheterization CTA and used to calculate the tortuosity index ([Curvilinear-Straight]/Curvilinear). The stented ductal length (SDL) was determined by catheter angiography after stent deployment by subtracting the aortic and pulmonary overhang from the total stent length. A linear regression model was created using an Akaike information criteria (AIC) analysis to identify CTA measurements that correlate with SDL. 31 patients met inclusion criteria. The SDL lies between the pre-stent CTA straight length (mean of 11.6 mm) and curvilinear length (mean of 17.8 mm) for most patients. As the PDA tortuosity index increases, the curvilinear length increases exponentially, while the SDL remains closer to the straight length. From our AIC analysis, only CTA straight length was significantly associated with SDL. Linear regression modeling predicts that the SDL is 1.14 times the CTA straight length (R = 0.97, p < 0.001). Pre-intervention CTA can aid in the selection of PDA stent length prior to catheterization. The SDL is well approximated by the pre-stent CTA straight length with a small correction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00246-024-03731-2 | DOI Listing |
J Cardiovasc Surg (Torino)
September 2025
Catheterization Laboratory, Montevergine Clinic, Mercogliano, Avellino, Italy -
Background: Lower extremity arterial disease is a prevalent vascular condition leading to ischemic symptoms and increased risk of cardiovascular events. Drug-eluting stents have improved outcomes by reducing restenosis, with sirolimus emerging as a promising alternative to paclitaxel due to its safer profile. This study evaluates the efficacy and safety of novel polymer-free Amphilimus formulation (Sirolimus + fatty acid) eluting self-expanding stent in the treatment of femoropopliteal disease in a real-world population.
View Article and Find Full Text PDFInterv Neuroradiol
September 2025
Department of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.
BackgroundA stable guiding system is essential for successful carotid artery stenting (CAS), particularly when navigating tortuous aortic or supra-aortic anatomy. However, data on the mechanical behavior of stent delivery systems remain scarce.ObjectiveTo assess and compare the bending stiffness and trackability of five commercially available carotid stent delivery systems using bench-top experiments.
View Article and Find Full Text PDFCan J Urol
August 2025
Department of Urology, Mayo Clinic Phoenix, Boulevard Phoenix, AZ 85054, USA.
Objectives: Previous studies have shown conflicting results concerning the optimal duration of ureteral stenting after endourologic treatment of stone disease, its effect on patient comfort, and the necessity for emergent, unscheduled care. This study assessed the impact of stent duration, sex, and other patient-associated factors on reported pain scores using a large, international prospective registry.
Methods: A prospective observational patient registry on ureteral stents from 10 institutions in 4 countries (United States, Canada, France, and Japan) from 2020-2023 was assessed.
Cardiol Young
September 2025
Cardiology, Paediatric Heart Centre, Skåne University Hospital, Lund, Sweden.
Capillary leak syndrome is a serious postoperative complication in neonates and infants after open-heart surgery for CHD. The aim of this study was to investigate the relationship between sternal opening width and the occurrence of capillary leak syndrome in patients undergoing cardiac surgery with delayed sternal closure.We retrospectively analysed the clinical data of neonates and infants (aged < 12 months) who underwent open-heart surgery with delayed sternal closure at our institution between January 2016 and December 2021.
View Article and Find Full Text PDFClin Radiol
August 2025
Department of Radiology, Faculty of Medicine, Bezmialem Vakif University, +34093, Istanbul, Turkey. Electronic address:
Aim: This study aimed to evaluate whether preoperative computed tomography (CT)-based morphological parameters predict the clinical success of self-expanding metallic stents (SEMS) in malignant colorectal obstruction.
Materials And Methods: Sixty-six patients with acute malignant colonic obstruction who underwent SEMS placement between 2016 and 2021 were retrospectively analysed. Tumour length, wall thickness, and lumen diameter were measured on preoperative CT, and ratios with SEMS dimensions were calculated.