A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Highly Sensitive Flow Cytometry Biosensor with a High Signal-to-Background Ratio for FEN1 Analysis via Solid-Phase Interface-Mediated Primer Exchange Reaction Amplification. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Flap endonuclease 1 (FEN1) is a specific enzyme capable of recognizing and cleaving triplex DNA structures and releasing 5'-flap fragments. It plays a crucial role in the DNA metabolism of cells, participating in DNA replication and the repair of damaged DNA. Additionally, FEN1 is overexpressed in various tumor tissues, promoting tumor progression and drug resistance through different regulatory mechanisms. However, few significant advancements have been made in sensitive analytical methods for detecting FEN1. Herein, in this study, we present a highly sensitive flow cytometry biosensor with solid-phase interface-mediated primer exchange reaction amplification (FCsperA) for FEN1 analysis. By comparing homogeneous PER amplification (h-PER), we found that solid-phase interface-mediated PER amplification (s-PER) effectively suppressed background signals, leading to a higher signal-to-background (S/B) ratio exceeding ∼46-fold when FEN1 was at 1 × 10 U/μL. Combining the high efficiency of s-PER, the strong suppression of background signals, and the highly precise flow cytometry assay, FCsperA showed high sensitivity, with a limit of detection (LOD) for FEN1 of 2.53 × 10 U/μL. Notably, FCsperA exhibited high selectivity and exceptional anti-interference ability, making it applicable for detecting FEN1 in cells and serum samples. The outstanding performance of FCsperA allowed for sensing FEN1 in ∼10 cancer cells. Additionally, FCsperA demonstrated the potential for screening inhibitors of FEN1.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.4c04564DOI Listing

Publication Analysis

Top Keywords

flow cytometry
12
solid-phase interface-mediated
12
fen1
10
highly sensitive
8
sensitive flow
8
cytometry biosensor
8
fen1 analysis
8
interface-mediated primer
8
primer exchange
8
exchange reaction
8

Similar Publications