Article Abstract

In percutaneous pelvic trauma surgery, accurate placement of Kirschner wires (K-wires) is crucial to ensure effective fracture fixation and avoid complications due to breaching the cortical bone along an unsuitable trajectory. Surgical navigation via mixed reality (MR) can help achieve precise wire placement in a low-profile form factor. Current approaches in this domain are as yet unsuitable for real-world deployment because they fall short of guaranteeing accurate visual feedback due to uncontrolled bending of the wire. To ensure accurate feedback, StraightTrack, an MR navigation system designed for percutaneous wire placement in complex anatomy, is introduced. StraightTrack features a marker body equipped with a rigid access cannula that mitigates wire bending due to interactions with soft tissue and a covered bony surface. Integrated with an optical see-through head-mounted display capable of tracking the cannula body, StraightTrack offers real-time 3D visualization and guidance without external trackers, which are prone to losing line-of-sight. In phantom experiments with two experienced orthopedic surgeons, StraightTrack improves wire placement accuracy, achieving the ideal trajectory within   mm and , compared to over 12.08  mm and 4.07 for comparable methods. As MR navigation systems continue to mature, StraightTrack realizes their potential for internal fracture fixation and other percutaneous orthopedic procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11665788PMC
http://dx.doi.org/10.1049/htl2.12103DOI Listing

Publication Analysis

Top Keywords

wire placement
12
mixed reality
8
navigation system
8
fracture fixation
8
straighttrack
6
wire
5
straighttrack mixed
4
navigation
4
reality navigation
4
percutaneous
4

Similar Publications

Capitate Osteochondral Graft for Reconstruction of Unstable Proximal Interphalangeal Joint Injury.

JBJS Essent Surg Tech

September 2025

Division of Hand and Reconstructive Microsurgery, Department of Orthopedics, Olympia Hospital & Research Centre, Trichy, Tamilnadu, India.

Background: Hemi-hamate osteochondral grafting is a surgical technique that is utilized to reconstruct the proximal interphalangeal (PIP) joint in cases of unstable dorsal fracture-dislocation with >50% articular surface involvement. However, hemi-hamate osteochondral grafting can be technically challenging, has been reported to have various technical modifications, and can lead to complications such as overstuffing of the joint. This surgical technique article describes successful PIP joint reconstruction with use of a hemi-capitate osteochondral graft, which may offer a viable alternative to hemi-hamate osteochondral graft.

View Article and Find Full Text PDF

Precision Placement of Decompression Tube in Large Cysts Using Guide Wire Assistance - A Technical Note.

J Stomatol Oral Maxillofac Surg

September 2025

Department of Oral and Maxillofacial Surgery, Army College of Dental Sciences, Secunderabad, Telangana, India. Electronic address:

We describe a novel technique in which a guide wire is used for the placement of a decompression tube in patients with large odontogenic cysts involving crucial structures. This technique facilitates precise placement of the tube, rather than blindly positioning it within the space.

View Article and Find Full Text PDF

Objective: To evaluate the feasibility and accuracy of customized 3-D-printed casts, created using virtual surgical planning, to guide wire placement for external skeletal fixation in the canine radius.

Methods: This experimental cadaver study used normal forelimbs from medium-sized canine cadavers (19 to 23 kg). Computed tomography scans were performed to generate 3-D bone and soft tissue models.

View Article and Find Full Text PDF

Objective: To demonstrate a detailed procedural guide for right ventricular outflow tract (RVOT) stent placement for palliation of tetralogy of Fallot and pulmonary stenosis in a patient weighing <2 kg.

Key Steps: Obtain wire position with an 0.018-inch Hi-Torque floppy wire in a distal branch pulmonary artery.

View Article and Find Full Text PDF

A novel protocol for the characterization of ureteral stent echogenicity.

BMC Urol

September 2025

Department of Urology, School of Medicine, University of California, 9300 Campus Point Drive, La Jolla, San Diego, CA, 92037, USA.

Background: Decreasing radiation exposure in renal colic management involves revisiting diagnostic, intraoperative, and postoperative practices. One approach is a shift in procedural standards from intraoperative fluoroscopy to ultrasonography. Despite the increased implementation of ultrasound in urology, the ultrasound visibility or echogenicity of various stents is not well-studied.

View Article and Find Full Text PDF