Article Abstract

Objective: Cochlear nerve deficiency (CND) accounts for about one-third of congenital hearing loss cases and presents several challenges during management. Currently, cochlear implant (CI) and auditory brainstem implants (ABI) represent the primary management options for CND. However, robust evidence on the outcomes of different CND management approaches remains limited. Therefore, this systematic review seeks to update and assess the effectiveness of various CND management approaches.

Databases Reviewed: PubMed, Scopus, Web of Science, and CENTRAL databases.

Methods: We conducted an online bibliographic search across these databases. We included both interventional and observational studies evaluating CND management outcomes.

Results: Of the 25 studies included, there were retrospective chart reviews, prospective observational studies, and one phase I clinical trial. Most studies focused on children with cochlear nerve aplasia or hypoplasia, with one study including patients with CHARGE syndrome. The mean age at the time of operation ranged from 0.5 to 4.5 years. Tools like the categories of auditory performance (CAP), speech intelligibility rating (SIR), and speech perception category (SPC) were commonly employed. CI outcomes were reported in 17 studies, while ABI outcomes were reported in 4 studies. The study found that the outcomes of both interventions were variable across the included studies.

Conclusion: While CI is feasible and an option in children with CND, its overall effectiveness is limited in some cases like cochlear nerve aplasia. Conversely, ABI appears to be a promising alternative with better auditory, speech, and learning outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00405-024-09087-wDOI Listing

Publication Analysis

Top Keywords

cochlear nerve
16
cnd management
12
nerve deficiency
8
systematic review
8
observational studies
8
nerve aplasia
8
outcomes reported
8
reported studies
8
cnd
6
studies
6

Similar Publications

Conductive nanocomposite hydrogels (CNHs) represent a promising tool in neural tissue engineering, offering tailored electroactive microenvironments to address the complex challenges of neural repair. This systematic scoping review, conducted in accordance with PRISMA-ScR guidelines, synthesizes recent advancements in CNH design, functionality, and therapeutic efficacy for central and peripheral nervous system (CNS and PNS) applications. The analysis of 125 studies reveals a growing emphasis on multifunctional materials, with carbon-based nanomaterials (CNTs, graphene derivatives; 36.

View Article and Find Full Text PDF

BACKGROUND Duplicated internal auditory canal (dIAC) is a rare congenital temporal bone anomaly associated with ipsilateral sensorineural hearing loss (SNHL). The Bonebridge bone conduction implant has a magnet, an internal transducer, and an external audio processor. This report is of a 14-year-old girl with unilateral SNHL and vestibulocochlear nerve (VIII cranial nerve) aplasia due to dIAC who was treated with a Bonebridge bone conduction implant.

View Article and Find Full Text PDF

Objective: This study aims to evaluate long-term auditory outcomes in patients with inner ear malformations (IEMs) treated with cochlear or auditory brainstem implants (CI/ABI), and to assess the influence of anatomical subtype, electrode design, insertion depth, and genetic/syndromic background on hearing performance over a 10-year follow-up.

Methods: We conducted a prospective cohort study including patients with radiologically confirmed IEMs and bilateral severe-to-profound hearing loss, all of whom underwent implantation and completed at least 10 years of follow-up. Outcomes were assessed using pure-tone average (PTA) and speech recognition scores (SRS) at defined intervals.

View Article and Find Full Text PDF

Vestibular Schwannomas are frequent tumors of the cerebellopontine angle, classically presenting with cochlear and facial nerve alteration. They tend to have histopathological and intratumoral degeneration seen on MRI, and can cause CSF obstruction with hydrocephalus with subsequent visual loss. We present a case of bilateral visual loss from papilledema, with no history of hydrocephalus or increased intracranial pressure.

View Article and Find Full Text PDF

Investigating cochlear cellular dynamics in neurofibromatosis type 2-associated schwannomatosis: a histopathological study.

Front Neurol

August 2025

The Eaton-Peabody Laboratories, The Massachusetts Eye and Ear Department of Otolaryngology - Head and Neck Surgery, Boston, MA, United States.

Sensorineural hearing loss (SNHL) is a hallmark symptom in patients with neurofibromatosis type 2-associated schwannomatosis (NF2-SWN), a genetic condition caused by mutations in the Neurofibromin II gene that encodes the tumor suppressor protein Moesin-Ezrin-Radixin-Like Protein (Merlin; also known as schwannomin). These mutations lead to the development of various tumors, including schwannomas, ependymomas and meningiomas along the vestibular nerve and the cerebellopontine angle. Original theories attributed SNHL in NF2-SWN to the mechanical compression of the vestibulocochlear nerve from the tumor itself, in addition to secretion of toxic tumor byproducts.

View Article and Find Full Text PDF