Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Measurement of anterior chamber depth (ACD), an important marker for the screening of primary angle-closure glaucoma, requires biometry, which is not readily used. This study assessed the relationship between ACD and health check-up data findings from participants with good corrected visual acuity in Japan. Participants underwent ophthalmic, anthropometric, and hematological assessments. The mean ACD of all 3060 participants was 3.33 ± 0.34 mm [2.22-4.72 mm]. Multivariable linear regression analysis was performed to determine factors that were significantly correlated with ACD, and logistic regression analysis was performed to predict ACD < 2.70 mm. Multivariable linear regression analysis showed that age, sex, intraocular pressure, spherical equivalent refractive error (SER), height, and fasting blood sugar levels significantly correlated with ACD (P < 0.05). Logistic regression analysis showed that age, sex, and SER were the best predictors of ACD < 2.70 mm. The area under receiving operator characteristic curves of 'age and SER' and 'age, SER, and sex' were 0.821 and 0.835, respectively, with no significant difference (P = 0.122). In conclusion, ACD correlates with several parameters, and age and SER may be particularly important for predicting ACD in participants undergoing health checkups.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11621401PMC
http://dx.doi.org/10.1038/s41598-024-82096-1DOI Listing

Publication Analysis

Top Keywords

anterior chamber
8
chamber depth
8
regression analysis
8
analysis performed
8
assessment factors
4
factors anterior
4
depth data
4
data health
4
health checkup
4
participants
4

Similar Publications

Background: To describe clinical features, risk factors and outcomes of out-of-the-bag (OTB) intraocular lens (IOL) dislocation in dead bag syndrome (DBS).

Methods: Retrospective review of a single-surgeon series of eyes with IOLs that developed OTB IOL dislocation, managed at Singapore National Eye Centre (January 2014-December 2021), with a minimum of 6 months of follow-up. Eyes with OTB IOL dislocation following secondary IOL implantation and intraoperative capsule complications were excluded.

View Article and Find Full Text PDF

Two patients (a 7-year-old female and a 61-year-old male) had poor intraocular pressure control after XEN gel stent implantation. During the process of filtering bleb repair, the XEN gel implant retreated into the anterior chamber, and the limbal and corneal incisions were made. After the implant in the anterior chamber was taken out, it was implanted into the anterior chamber again from the original scleral tunnel for the female patient, while it was re-punctured into the anterior chamber with a 1-ml syringe needle at another site for the male patient.

View Article and Find Full Text PDF

[Experimental optimization of paraffin sectioning techniques for the eyeball].

Zhonghua Yan Ke Za Zhi

September 2025

Ophthalmology Medical Center, The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory for the Prevention and Treatment of Major Blinding Eye Diseases, Chongqing Branch (Municipality Division) of National Clinical Research Centre for Ocular Diseases, Chongqing 400016,

To explore optimized protocols for paraffin section preparation of the eyeball to enhance the histological visualization of key ocular structures. It was an experimental research, conducted from September 2022 to September 2024. The first experiment involved 18 porcine eyeballs, which were divided into five groups (six subgroups) by the random number table method.

View Article and Find Full Text PDF

Purpose: To compare refractive prediction accuracy using simulated keratometry (SimK) measurements obtained from a Scheimpflug tomographer (Pentacam AXL, Oculus) versus keratometry (K) measurements obtained from an optical biometer utilizing telecentric keratometry (IOLMaster 700 (IOLM700), Carl Zeiss Meditec AG) applied to modern IOL power calculation formulas.

Design: Retrospective accuracy and validity analysis METHODS: Setting: Private practice center STUDY POPULATION: Five hundred eighty-nine eyes with preoperative SimK and K measurements undergoing phacoemulsification and implantation of monofocal IOL (Clareon SY60WF IOL, Alcon Laboratories, Inc.).

View Article and Find Full Text PDF