Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
In the field of fringe projection profilometry, phase sensitivity is a critical factor influencing the precision of object measurements. Traditional techniques that employ basic horizontal or vertical fringe projection often do not achieve optimal levels of phase sensitivity. The identification of the fringe angle that exhibits optimal phase sensitivity has been a significant area of research. The present study introduces a novel method for determining the optimal fringe angle, facilitating 3D reconstruction without the need for equipment adjustments. Initially, the optimal fringe is derived through mathematical analysis, and the system's position within each coordinate system is standardized, leading to the determination of the optimal fringe angle in the world coordinate system. Subsequently, an optimal fringe pattern, akin to that produced by a rotating projector, is generated based on the concept of rotation around a central point, with corresponding adjustments made to the calibration parameters. Finally, the optimal fringe is projected onto the target object for 3D reconstruction, thereby validating the proposed method. The experimental results demonstrate that this approach accurately identifies the optimal fringe angle, significantly enhancing both phase sensitivity and measurement accuracy. The accuracy of the measurement is significantly greater, by an order of magnitude, compared to the traditional method, with the error being approximately 50% of that associated with the currently established improved method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11598083 | PMC |
http://dx.doi.org/10.3390/s24227234 | DOI Listing |