A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparison of Visual Performance Between Mix-and-Match and Bilateral Implantation of Rotationally Asymmetric Multifocal Intraocular Lenses. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To evaluate and compare the clinical outcomes of rotationally asymmetric multifocal intraocular lenses (IOLs) in a mix-and-match approach or bilateral implantation.

Methods: In this prospective study, patients were split into two groups based on the types of IOLs implanted. The mix group received mix-and-match implantation of a LENTIS Mplus LS-313 +1.50D IOL in the dominant eye and a LENTIS Mplus LS-313 +3.0D IOL in the fellow eye. The bilateral group received bilateral implantation of LENTIS Mplus LS-313 +3.00D IOLs. A three-month follow-up was performed after the surgery. Binocular visual acuity at various distances, subjective refraction and defocus curves were assessed. Subjective questionnaires included the overall satisfaction, a self-assessment of visual quality, spectacle independence, and presence of photic phenomena were completed.

Results: The study was completed by 52 patients in total (25 mix-and-match, 27 bilateral). The mean binocular uncorrected intermediate visual acuity in the mix group and the bilateral group were 0.10 ± 0.12 logMAR and 0.23 ± 0.14 logMAR, respectively, demonstrating a significant difference (P = 0.005). The mix group performed better in intermediate vision (range: -1.00 to -2.00 D) than the bilateral group (all P< 0.05), according to binocular defocus curves. About 92.0% of patients in the mix group did not need spectacles for intermediate distance vision compared to 59.26% in the bilateral group (P = 0.0001).

Conclusion: The mix-and-match implantation of the +1.50D and +3.00D rotationally asymmetric multifocal IOLs provided good binocular visual outcomes and resulted in better intermediate vision than bilateral implantation of +3.00D IOLs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11584345PMC
http://dx.doi.org/10.2147/OPTH.S487162DOI Listing

Publication Analysis

Top Keywords

mix group
16
bilateral group
16
bilateral implantation
12
rotationally asymmetric
12
asymmetric multifocal
12
lentis mplus
12
mplus ls-313
12
bilateral
9
mix-and-match bilateral
8
multifocal intraocular
8

Similar Publications