Magnetoactive elastomer-based dynamic urethral support device for stress urinary incontinence.

Acta Biomater

Texas A&M University, Department of Biomedical Engineering, College Station, TX, United States; Texas A&M University, Department of Materials Science and Engineering, College Station, TX, United States. Electronic address:

Published: January 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Stress urinary incontinence (SUI) is the involuntary leakage of urine in response to increased intra-abdominal pressure during episodes of exertion. A common treatment method for SUI is sling implantation underneath the urethra to provide support. Most current sling procedures, however, cannot adjust urethral tension postoperatively. To address this limitation, we designed a soft magnetoactive elastomer (MAE) device capable of changing shape in response to moderate magnetic fields. To ensure shape change after fibrotic scar tissue encapsulation, MAE devices were embedded in agar gels with different stiffnesses, and their shape change was studied in response to up to 200 mT magnetic fields. A simple in vitro model of the lower urinary tract was designed to study device performance. Flow time was measured as a function of pressure in the simulated bladder as the model system leaked before and after activating sling with a hand-held magnet. MAE devices embedded in agar gel (100 kPa) in hammock-like configuration achieved 4.7% ± 1.1% change in height. Devices with silica-coated magnetic particles showed minimal loss in mass after two weeks in accelerated oxidative (2.36% ± 1.55%) and hydrolytic (0.58% ± 0.25%) conditions. Placing a sling under the model urethra provided urethral support; thus, increasing its resistance to flow. Normalized flow time significantly reduced from 1.56 ± 0.18 to 1.11 ± 0.16 when magnetic field was applied, indicating urethral support modulation at 60 cm-HO. This dynamic sling, powered externally with physiologically safe magnetic fields, allowed for urethral support modulation in a model of the lower urinary tract. STATEMENT OF SIGNIFICANCE: Stress urinary incontinence (SUI) affects up to half the adult women during their lifetime, and slings are commonly used to treat severe cases. While sling implantation is minimally invasive and offers moderate to high cure rates, long-term sling complications, such as urine retention, remain a significant concern. Available adjustable SUI devices often require invasive surgeries, implantable electronics, and multiple mechanical components, increasing the overall invasiveness. Here, we report a proof of concept for using shape-morphing biomaterials to fabricate a dynamic device that can provide continence support and be triggered to change shape, enabling complete voiding. Such a dynamic device may prevent many complications associated with traditional slings and improve quality of life for women suffering from severe SUI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2024.11.039DOI Listing

Publication Analysis

Top Keywords

urethral support
16
stress urinary
12
urinary incontinence
12
magnetic fields
12
incontinence sui
8
sling implantation
8
shape change
8
mae devices
8
devices embedded
8
embedded agar
8

Similar Publications

Background: Bladder outlet obstruction (BOO) due to benign prostatic hyperplasia (BPH) is a common urological condition in aging men, often requiring surgical intervention for symptom relief.

Objective: To evaluate the therapeutic efficacy and complication profile of monopolar transurethral resection of the prostate (TURP) in patients with BOO.

Methodology: This descriptive observational study was conducted at the Department of Urology, Hayatabad Medical Complex, Peshawar, and Akhtar Saeed Trust Hospital, Lahore, from August 2022 to July 2024.

View Article and Find Full Text PDF

Objective: This study aimed to investigate the risk factors for catheter-associated urinary tract infection (CAUTI) in patients with ischaemic stroke and provide a scientific basis for developing targeted preventive and nursing measures.

Methods: A retrospective cohort study was conducted to study patients with ischaemic stroke and indwelling catheterisation admitted to the Emergency Department of Beijing Tiantan Hospital, Capital Medical University from December 2023 to February 2025. During hospitalisation, quality control was carried out in strict accordance with the consistent nursing operation of the patient's urethral catheter insertion and daily maintenance of the urinary catheter.

View Article and Find Full Text PDF

Pregnancy Following Clam Cystoplasty and Mitrofanoff Procedure in a Patient With Fowler's Syndrome and Detrusor Overactivity.

Cureus

August 2025

Department of Obstetrics and Gynecology, Dumfries and Galloway Royal Infirmary, Dumfries, GBR.

Fowler's syndrome causes urinary retention due to failure of the urethral sphincter to relax. Management aims for complete bladder emptying, typically via intermittent self-catheterization. If conservative treatment fails, detrusor overactivity with Fowler's syndrome may be managed surgically using clam cystoplasty and the Mitrofanoff procedure to increase bladder capacity and reduce pressure.

View Article and Find Full Text PDF

Background: Acellular bi-layer silk fibroin (BLSF) scaffolds represent potential alternatives to autologous tissue grafts for substitution urethroplasty (SU) given their ability to repair focal urethral defects in animal models. However, in patients with a severe fibrotic urethral plate, single or staged SU are often required to restore organ continuity. Currently, the feasibility of tubular BLSF grafts for urethral replacement is unknown.

View Article and Find Full Text PDF

Penile strangulation is a rare urological emergency that can lead to severe complications such as ischemia, necrosis, and urethral injury. We present a case of a 76-year-old man who presented to the emergency department with severe penile pain and swelling after applying five metallic rings to enhance erection during sexual intercourse. The patient had a history of erectile dysfunction and had been using phosphodiesterase inhibitors with a moderate response.

View Article and Find Full Text PDF