A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A New Easy-to-Perform Flow Cytometry Assay for Determining Bacterial- and Viral-Infection-Induced Polymorphonuclear Neutrophil and Monocyte Membrane Marker Modulation in Febrile Patients. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We developed a flow cytometry (FC) assay enabling the rapid and accurate identification of bacterial and viral infections using whole blood samples. The streamlined flow cytometry assay is designed to be user-friendly, making it accessible even for operators with limited experience in FC techniques. The key components of the assay focus on the expression levels of specific surface markers-CD64 on polymorphonuclear neutrophils (PMN) as a marker for bacterial infection, and CD169 on monocytes (MO) for viral infection. The strong performance indicated by an area under the receiver operating characteristic (ROC) curve of 0.94 for both PMN CD64 positive predictive value (PPV) 97.96% and negative predictive value (NPV) 76.67%, and MO CD169 PPV 82.6% and NPV 86.9%, highlight the assay's robustness in differentiating between bacterial and viral infections accurately. The FC assay includes the assessment of immune system status through HLA-DR and IL-1R2 modulation in MO, providing a useful insight into the patients' immune response. The significant increase in the frequency of MO exhibiting reduced HLA-DR expression and elevated IL-1R2 levels in infected patients (compared to healthy controls) underscores the potential of these markers as indicators of infection severity. Although the overall correlation between HLA-DR and IL-1R2 expression levels was not significant across all patients, there was a trend in patients with more severe disease suggesting that these markers may have the potential to assist in stratifying patient risk. The present FC assay has the potential to become routine in the clinical microbiology laboratory community and to be helpful in guiding clinical decision making.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11547050PMC
http://dx.doi.org/10.3390/ijms252111632DOI Listing

Publication Analysis

Top Keywords

flow cytometry
12
cytometry assay
12
bacterial viral
8
viral infections
8
expression levels
8
hla-dr il-1r2
8
assay
6
easy-to-perform flow
4
assay determining
4
determining bacterial-
4

Similar Publications