A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study. | LitMetric

The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study.

Clin Oral Investig

Department of Prosthodontics, Faculty of Dentistry, Recep Tayyip Erdogan University, Islampasa, Menderes Blvd. No:612 Rize, Rize, 53020, Turkey.

Published: November 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: To investigate the effects of denture cleansers on the various properties of CAD/CAM and heat-polymerized polymethyl methacrylate (PMMA).

Materials And Methods: Two different brands of heat-polymerized and two of milled PMMA were fabricated (n = 50), in total 200. Each group was randomly divided into five subgroups (n = 10): control groups (D1) kept in distilled water, cleaning tablets (D2, D3), neutral (D4) and acidic electrolyzed acid water (EAW) (D5). Surface roughness, hardness and flexural strength values were evaluated. Data were statistically analyzed with two-way ANOVA and Tukey post hoc test for comparison (p<0.05).

Results: The milled group showed significantly lower surface roughness, greater surface hardness, and higher flexural strength values than heat polymerized denture bases (p<0.05). The denture cleansers had no significant effect on the surface roughness values of the milled specimens (p>0.05), whereas the specimens in the heat-polymerized groups and treated with D5 showed greater surface roughness values compared with the other cleaning agents (p > 0.05). The denture cleansers had no significant effect on surface hardness and flexural strength of heat polymerize groups (p > 0.05). However, D2, D3 and D5 cleaning agent decreased the hardness values of the milled group (p<0.05) and D5 cleaning agent decreased the flexural strength of the milled group (p<0.05).

Conclusions: It was observed that the applied denture cleansers affected the surface roughness, surface hardness, and flexural strength values of both denture bases but within a clinically acceptable value.

Clinical Relevance: CAD/CAM denture bases showed significantly higher physical and mechanical properties than to heat-polymerized base materials. Although the applied neutral EAW cleaners give desired results for denture bases, clinical studies are needed for biological compatibility.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-024-06016-3DOI Listing

Publication Analysis

Top Keywords

denture cleansers
12
properties cad/cam
8
cad/cam heat-polymerized
8
hardness flexural
8
flexural strength
8
denture
4
cleansers physical
4
physical mechanical
4
mechanical properties
4
heat-polymerized denture
4

Similar Publications