Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objectives: To investigate the effects of denture cleansers on the various properties of CAD/CAM and heat-polymerized polymethyl methacrylate (PMMA).
Materials And Methods: Two different brands of heat-polymerized and two of milled PMMA were fabricated (n = 50), in total 200. Each group was randomly divided into five subgroups (n = 10): control groups (D1) kept in distilled water, cleaning tablets (D2, D3), neutral (D4) and acidic electrolyzed acid water (EAW) (D5). Surface roughness, hardness and flexural strength values were evaluated. Data were statistically analyzed with two-way ANOVA and Tukey post hoc test for comparison (p<0.05).
Results: The milled group showed significantly lower surface roughness, greater surface hardness, and higher flexural strength values than heat polymerized denture bases (p<0.05). The denture cleansers had no significant effect on the surface roughness values of the milled specimens (p>0.05), whereas the specimens in the heat-polymerized groups and treated with D5 showed greater surface roughness values compared with the other cleaning agents (p > 0.05). The denture cleansers had no significant effect on surface hardness and flexural strength of heat polymerize groups (p > 0.05). However, D2, D3 and D5 cleaning agent decreased the hardness values of the milled group (p<0.05) and D5 cleaning agent decreased the flexural strength of the milled group (p<0.05).
Conclusions: It was observed that the applied denture cleansers affected the surface roughness, surface hardness, and flexural strength values of both denture bases but within a clinically acceptable value.
Clinical Relevance: CAD/CAM denture bases showed significantly higher physical and mechanical properties than to heat-polymerized base materials. Although the applied neutral EAW cleaners give desired results for denture bases, clinical studies are needed for biological compatibility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00784-024-06016-3 | DOI Listing |