A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Decoupling control strategy of three-port DC-DC converter based on model prediction. | LitMetric

Decoupling control strategy of three-port DC-DC converter based on model prediction.

Sci Rep

School of Electrical Information Engineering, North Minzu University, Yinchuan, 750021, China.

Published: November 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Due to the use of multi winding high-frequency isolation transformers in the three port isolated bidirectional DC-DC converter to achieve port isolation and power transmission, there is a power coupling problem between each port. This article proposes a Model Prediction Control (MPC) strategy to address this issue. Considering the control objectives for each port of the Triple Active Bridge (TAB) DC-DC converter, a discrete predictive model of the TAB converter is established based on phase-shifting modulation and average model. The MPC problem is solved optimally and a predictive controller is designed with control accuracy to achieve decoupling control effect between each port. And the traditional single voltage closed-loop control, diagonal matrix decoupling control, and model predictive control proposed in this paper are compared through simulation. Finally, a TAB converter experimental platform is built based on the DSP control chip TMS320F28335. The experimental results are verified the effectiveness and superiority of the proposed method, as well as its faster dynamic characteristics and power decoupling ability between each port.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11531517PMC
http://dx.doi.org/10.1038/s41598-024-74814-6DOI Listing

Publication Analysis

Top Keywords

decoupling control
12
dc-dc converter
12
model prediction
8
control
8
tab converter
8
port
6
converter
5
model
5
decoupling
4
control strategy
4

Similar Publications