Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Zero echo time (ZTE) imaging is a relatively new magnetic resonance (MR) pulse sequence that provides bone-soft tissue contrast similar to that of computed tomography (CT). We sought to (1) determine the accuracy of ZTE MRI for the diagnosis of common ankle fractures and (2) investigate whether ZTE imaging sequences are equivalent to the gold standard of CT for the characterization of fracture fragments. We conducted a prospective case series of 54 patients with acute ankle trauma, in whom ZTE MRI was performed, followed by surgical reduction. Fractures on the ZTE sequence were correlated with the operative report as the reference standard. Raw agreement (%) and correlation (κ) were calculated. Selected fracture fragments were measured in 2 dimensions (anterior-posterior and superior-inferior) on corresponding sagittal ZTE and CT images by 3 independent radiologists to determine reliability. The ZTE sequence demonstrated 47 distal fibular, 17 medial malleolar, 24 posterior malleolar, 5 anterior talofibular ligament avulsion, and 4 distal tibial fractures on the 54 cases. Raw agreement with operative findings was 95% (range: 86%-100%) and correlation almost perfect (0.960 [0.926-0.995]). Fragment characterization was accurate and repeatable. Intraobserver and interobserver agreement was excellent. Our case series suggests that the use of the MRI ZTE sequence may provide images with CT-like contrast for characterizing acute ankle fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11512459PMC
http://dx.doi.org/10.1177/15563316231187383DOI Listing

Publication Analysis

Top Keywords

ankle fractures
12
zte sequence
12
echo time
8
mri diagnosis
8
zte
8
zte imaging
8
zte mri
8
fracture fragments
8
case series
8
acute ankle
8

Similar Publications

Background: Isolated sustentaculum tali fractures among pediatric cohorts represent an exceedingly uncommon entity (<1% of all calcaneal fractures), with limited published evidence regarding operative intervention in prepubescent patients. Diagnostic complexities emerge from radiographically indiscernible fracture patterns, mandating cross-sectional imaging modalities. This case study documents the youngest reported patient (7-year-old female) and introduces the first comprehensive morphometric analysis of fracture characteristics and clinical outcomes following surgical management via open reduction and internal fixation (ORIF) utilizing Kirschner wire (K-wire) stabilization.

View Article and Find Full Text PDF

Background: Despite considerable improvements in surgical treatment strategies for unstable ankle fractures, long-term follow-up studies on conventional treatment strategies are missing. The aim of the study was to assess the patient-reported long-term outcome (≥15 years) following surgically treated ankle fractures.

Methods: Retrospective, single-center, outcome study with a current follow-up.

View Article and Find Full Text PDF

Elevated Risk of Postoperative Complications With Non-tobacco Nicotine Use Following Open Reduction and Internal Fixation of Ankle Fractures.

J Am Acad Orthop Surg

August 2025

From the Department of Medical Education, Texas A&M College of Medicine, Dallas, TX (Sontam, Toussaint, Hlavinka, Chavda, and Mbilinyi), and the Department of Orthopedic Surgery, Baylor University Medical Center, Dallas, TX (Zide).

Background: Smoking is a well-established risk factor for postoperative complications following open reduction and internal fixation (ORIF) for rotational ankle fractures. However, the effect of non-tobacco nicotine (NTN) use on these outcomes remains unclear, despite the increasing use of products such as vapes. This retrospective cohort study investigates whether perioperative NTN use is associated with increased postoperative complications following ankle ORIF compared with a nicotine-independent (NI) control group.

View Article and Find Full Text PDF

Higher precision and preservation of frontal plane alignment in slope-reducing infra-tubercle compared to retro-tubercle high tibial osteotomy.

Knee Surg Sports Traumatol Arthrosc

September 2025

Department of Orthopedic Surgery, APHM, CNRS, ISM, Institute of Movement Sciences, Sainte-Marguerite Hospital, Aix Marseille University, Marseille, France.

Purpose: Slope-reducing high tibial osteotomies (SR-HTOs) correct posterior tibial slope (PTS) abnormalities in patients with anterior knee instability, as in cases of anterior cruciate ligament (ACL) deficiency. The SR-HTO techniques, including infra-tubercle and retro-tubercle approaches, provide distinct benefits: retro-tubercle techniques help preserve patellofemoral joint mechanics, while infra-tubercle techniques are effective in mitigating iatrogenic varus. However, there is limited comparative literature available.

View Article and Find Full Text PDF

Patient Demographics and Risk Factors for Surgical Site Infections After Open Reduction and Internal Fixation for Bimalleolar Ankle Fractures.

J Am Acad Orthop Surg

August 2025

From the Department of Orthopaedic Surgery (Mastrokostas, and Monas), SUNY Downstate Health Sciences University, and the Maimonides Medical Center (Mastrokostas, Rodriguez, Lam, Razi, and Ng), Department of Orthopaedic Surgery, Brooklyn, NY.

Background: The purpose of this study was to identify the incidence and risk factors associated with surgical site infection (SSI) after open reduction and internal fixation of bimalleolar ankle fractures. Bimalleolar ankle fractures are one of the most common subtypes of ankle fractures, accounting for 15% to 20% of all ankle fractures. Recent studies have shown that 4.

View Article and Find Full Text PDF