A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Preoperative localization of pulmonary nodules by electromagnetic navigation bronchoscopy combined with methylene blue injection. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Electromagnetic navigation bronchoscopy (ENB) can help to accurately locate pulmonary nodules using a minimally invasive approach. This study sought to evaluate the clinical efficacy and safety of dye marking localization under the guidance of ENB followed by surgery.

Methods: A retrospective analysis was performed of 61 patients who underwent ENB localization using methylene blue dye marking before surgery at Shanghai General Hospital from October 2021 to February 2022. The clinical efficacy and safety of ENB localization and the related factors affecting the navigation time of ENB location were analyzed.

Results: ENB was performed on 170 pulmonary nodules in 61 patients with a median age of 60 [interquartile range (IQR), 18] years. The majority of patients (70.69%) had more than two pulmonary nodules. The median maximum nodule diameter was 10 (IQR, 8) mm, and 48.21% of the nodules were mixed ground-glass nodules. Median time for ENB navigation was 10.5 (IQR, 6) min. The navigation success rate was 92.96%, and the ENB location success rate was 95.89%. The rate of complications related to ENB localization was 1.64% (there was only one case of pulmonary hemorrhage). The multivariate analysis showed that the factors related to the navigation time included the node location (P=0.001) and location mode (P=0.04).

Conclusions: ENB-guided methylene blue injection is an effective and safe tool for localizing and marking pulmonary nodules, and can be used to assist the diagnosis and treatment of early lung cancer. The node location and location mode had significant effects on navigation time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11494549PMC
http://dx.doi.org/10.21037/jtd-24-1358DOI Listing

Publication Analysis

Top Keywords

pulmonary nodules
20
methylene blue
12
enb localization
12
navigation time
12
enb
9
electromagnetic navigation
8
navigation bronchoscopy
8
blue injection
8
clinical efficacy
8
efficacy safety
8

Similar Publications