A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Continuous Wavelet Transform as a Signal Processing Technique for Spectrofluorimetric Analysis of Rosuvastatin and Losartan: Greenness and Blueness Assessment. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this study, the application of continuous wavelet transform as a signal processing technique for the spectrofluorimetric determination of rosuvastatin and losartan is investigated. Both rosuvastatin and losartan exhibited native spectrofluorometric signals with severe overlapping peaks, making their simultaneous determination challenging. To address this issue, rbio 2.4 wavelet transformation was employed to obtain zero-crossing points in the synchronous fluorescence spectra of losartan and rosuvastatin at 346 and 408 nm, respectively, making their quantification possible. The developed method was validated according to the ICH guidelines and displayed high accuracy, precision, and specificity. The method exhibited excellent linearity over concentration ranges 0.2-2.0 and 0.25-2.0 μg/mL for losartan and rosuvastatin, respectively. In addition, LOD and LOQ were 0.046 and 0.140 μg/mL for losartan and 0.036 and 0.110 μg/mL for rosuvastatin, respectively, indicating the high sensitivity of the developed method. Moreover, greenness and blueness assessments were carried, revealing a high AGREE score of 0.71 and BAGI score of 77.5 for the developed method, making it a promising greener alternative for the reported chromatographic methods. Finally, the developed method was applied to the determination of rosuvastatin and losartan in pharmaceutical formulations, posing it as a powerful greener alternative in quality control laboratories.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bio.4928DOI Listing

Publication Analysis

Top Keywords

rosuvastatin losartan
16
developed method
16
continuous wavelet
8
wavelet transform
8
transform signal
8
signal processing
8
processing technique
8
technique spectrofluorimetric
8
greenness blueness
8
determination rosuvastatin
8

Similar Publications