98%
921
2 minutes
20
Background: To meet the WHO target of eradicating yaws by 2030, highly sensitive and specific diagnostic tools are needed. A multiplex Treponema pallidum-Haemophilus ducreyi loop-mediated isothermal amplification (TPHD-LAMP) test holds promise as a near-patient diagnostic tool for yaws and H ducreyi. We conducted a prospective evaluation in Cameroon, Côte d'Ivoire, Ghana, and the Republic of the Congo to determine the diagnostic accuracy of the TPHD-LAMP test, as well as to assess its acceptability, feasibility, and cost.
Methods: Active case searching within schools and communities was used to locate participants with clinically suspicious laws-like lesions. Individuals with serologically confirmed active yaws provided paired lesion swabs between March, 2021, and April, 2023. For each participant, one swab was tested with the TPHD-LAMP at a local district laboratory and the other with reference quantitative PCR (qPCR) tests conducted at national reference laboratories. The primary outcome was TPHD-LAMP test sensitivity and specificity compared with qPCR. Laboratory technicians were interviewed using a multiple-choice survey to gauge acceptability and feasibility of the TPHD-LAMP test. Costs of each test were calculated.
Findings: Of 3085 individuals with at least one suspected yaws lesion, 531 (17%) were serologically confirmed. We enrolled 493 participants with seropositive yaws and a further 32 with negative serology. The sensitivity of the TPHD-LAMP test for detecting T pallidum was 63% (95% CI 56-70) and the specificity was 66% (95% CI 61-71). Sensitivity and specificity for T pallidum improved to 73% (63-82; p=0·0065) and 75% (68-80; p=0·0003), respectively, in H ducreyi-negative samples. Interviews highlighted challenges in user-friendliness and practicality of the TPHD-LAMP test. The cost of the test per sample was one third of that of qPCR, although the TPHD-LAMP test entailed higher costs to establish the assay.
Interpretation: This was the first multi-country diagnostic evaluation of a molecular test for yaws. The TPHD-LAMP testing, in its current form, falls short of the WHO target product profile criteria for yaws diagnostics. These findings highlight the importance of assessing new diagnostics in real-world conditions to ensure their suitability for programmatic use.
Funding: The EDCTP2 programme supported by the EU.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S2214-109X(24)00324-3 | DOI Listing |
Lancet Glob Health
November 2024
Faculty of Infectious Diseases, London School of Hygiene & Tropical Medicine, London, UK; Hospital for Tropical Diseases, London, UK; Division of Infection and Immunity, University College London, London, UK.
Background: To meet the WHO target of eradicating yaws by 2030, highly sensitive and specific diagnostic tools are needed. A multiplex Treponema pallidum-Haemophilus ducreyi loop-mediated isothermal amplification (TPHD-LAMP) test holds promise as a near-patient diagnostic tool for yaws and H ducreyi. We conducted a prospective evaluation in Cameroon, Côte d'Ivoire, Ghana, and the Republic of the Congo to determine the diagnostic accuracy of the TPHD-LAMP test, as well as to assess its acceptability, feasibility, and cost.
View Article and Find Full Text PDFBMJ Open
March 2022
Clinical Research Department, London School of Hygiene and Tropical Medicine Faculty of Infectious and Tropical Diseases, London, UK.
Introduction: Yaws, caused by the bacterium subsp. is a neglected tropical disease targeted for eradication by 2030. Improved diagnostics will be essential to meet this goal.
View Article and Find Full Text PDFYaws, a neglected tropical disease caused by the bacterium Treponema pallidum subspecies pertenue, manifests as ulcerative skin lesions. Nucleic acid amplification tests, like loop-mediated isothermal amplification (LAMP), are versatile tools to distinguish yaws from infections that cause similar skin lesions, primarily Haemophilus ducreyi. We developed a novel molecular test to simultaneously detect T.
View Article and Find Full Text PDF