Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Graft infection, fistula, and mediastinitis are reported among the serious cardiovascular complications after a Bentall procedure. Surgery associated with antimicrobial treatment is usually recommended but not easily feasible in most cases. In this report, we describe a case of successful valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) in a patient with a degenerated bioconduit from a previously healed infectious endocarditis (IE). The TAVR procedure has been demonstrated to be a therapeutic option in selected cases with a previous history of IE who have been fully treated with antimicrobial therapy and who present a low risk of local re-infection and are deemed at prohibitive or high risk for surgical replacement. Data on TAVR on a bioconduit after a Bentall procedure are scarce. The present case underlines that a long follow-up and individualized treatment could improve the prognosis in patients with a history of prosthetic valve and aortic graft infection and severe valve dysfunction who cannot undergo surgical treatment. The 18F-labeled fluoro-2-deoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) result could be successfully employed in the decision algorithm. Long-term antibiotic treatment, which could be lifelong in some instances, could be a reasonable choice when the risk of recurrence is associated with the risk for the patient's life.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11480688PMC
http://dx.doi.org/10.7759/cureus.69453DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
8
infectious endocarditis
8
graft infection
8
bentall procedure
8
aortic valve-in-valve
4
valve-in-valve implantation
4
implantation patient
4
patient degeneratation
4
degeneratation biointegral
4
valve
4

Similar Publications

The efficacy of the remote monitoring system following transcatheter aortic valve replacement.

Cardiovasc Revasc Med

August 2025

Department of Cardiothoracic Surgery, NYU Langone Health, NY, United States of America. Electronic address:

Background: Transcatheter aortic valve replacement (TAVR) has become a cornerstone in the management of aortic valve disease. However, delayed complications after hospital discharge and readmission remain in an issue following TAVR. We aimed to evaluate the impact of remote monitoring systems on clinical outcomes after TAVR.

View Article and Find Full Text PDF

Spanish cardiac catheterization and coronary intervention registry. 34 official report of the Interventional Cardiology Association of the Spanish Society of Cardiology (1990-2024).

Rev Esp Cardiol (Engl Ed)

September 2025

Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, Madrid, España; Servicio de Cardiología, Hospital Clínico de Santiago de Compostela, Santiago de Compostela, España.

Introduction And Objectives: This report presents the 2024 activity data from the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC).

Methods: All interventional cardiology laboratories in Spain were invited to complete an online survey. Data analysis was conducted by an external company and then reviewed and presented by the ACI-SEC board.

View Article and Find Full Text PDF

Background: In transcatheter aortic valve replacement (TAVR), there is a notable "diabetes discrepancy", where worse/better/similar outcomes were all found for patients with diabetes mellitus (DM). Such divergent findings pose a challenge for clinicians to accurately assess the risks for DM patients undergoing TAVR. We hypothesized the presence of chronic complications could be linked to worse post-TAVR outcomes in DM patients.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a preferred treatment option for many patients with severe aortic stenosis, but concerns exist regarding safety in patients with nickel allergy due to metallic valve frames. We report a series of 7 patients with a history of nickel allergy who underwent TAVR. Preprocedural allergy evaluation varied, including patch testing or direct skin contact with valve fragments.