Rational: To validate a population-based input function (PBIF) model that alleviates the need for scanning since injection time in dynamic whole-body (WBdyn) PET.

Methods: Thirty-seven patients with suspected/known well-differentiated neuroendocrine tumors were included (GAPETNET trial NTC03576040). All WBdyn 68Ga-DOTATOC-PET/CT acquisitions were performed on a digital PET system (one heart-centered 6 min-step followed by nine WB-passes). The PBIF model was built from 20 image-derived input functions (IDIFs) obtained from a respective number of patients' WBdyn exams using an automated left-ventricle segmentation tool. All IDIF peaks were aligned to the median time-to-peak, normalized to patient weight and administrated activity, and then fitted to an exponential model function. PBIF was then applied to 17 independent patient studies by scaling it to match the respective IDIF section at 20-55 min post-injection time windows corresponding to WB-passes 3-7. The ratio of area under the curves (AUCs) of IDIFs and PBIF were compared using a Bland-Altman analysis (mean bias ± SD). The Patlak-estimated mean Ki for physiological uptake (Ki-liver and Ki-spleen) and tumor lesions (Ki-tumor) using either IDIF or PBIF were also compared.

Results: The mean AUC ratio (PBIF/IDIF) was 0.98 ± 0.06. The mean Ki bias between PBIF and IDIF was -2.6 ± 6.2% (confidence interval, CI: -5.8; 0.6). For Ki-spleen and Ki-tumor, low relative bias with low SD were found [4.65 ± 7.59% (CI: 0.26; 9.03) and 3.70 ± 8.29% (CI: -1.09; 8.49) respectively]. For Ki-liver analysis, relative bias and SD were slightly higher [7.43 ± 13.13% (CI: -0.15; 15.01)].

Conclusion: Our study showed that the PBIF approach allows for reduction in WBdyn DOTATOC-PET/CT acquisition times with a minimum gain of 20 min.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11464975PMC
http://dx.doi.org/10.3389/fnume.2022.941848DOI Listing

Publication Analysis

Top Keywords

function pbif
12
population-based input
8
input function
8
pbif
8
pbif applied
8
dynamic whole-body
8
pbif model
8
relative bias
8
applied dynamic
4
whole-body 68ga-dotatoc-pet/ct
4

Similar Publications

Use of relative Patlak plot Ki' images as an alternative to standard Patlak plot Ki images in clinical practice.

EJNMMI Res

August 2025

Department of Radiology, Graduate School of Medical and Dental Sciences, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan.

Background: The kinetic rate constant (Ki), derived from the Patlak slope, reflects F-FDG uptake and supports disease assessment. Standard Patlak Ki imaging requires prolonged dynamic acquisition and full arterial input function (IF), limiting clinical feasibility. The relative Patlak plot omits the early-phase IF and focuses on the linear phase of tracer kinetics using only late dynamic data and a partially sampled IF.

View Article and Find Full Text PDF

Background: This study focuses on modeling a population-based input function (PBIF) in dynamic ⁶⁸Ga-DOTATOC PET/CT exams, with the aim of developing clinically adoptable protocols. The PBIF is derived from an image-derived input function (IDIF), ensuring a non-invasive and standardized approach to tracer kinetic modeling.

Methods: Patients with well-differentiated neuroendocrine tumors were included from the GAPETNET clinical trial (n = 37), divided into a PBIF modeling group (n = 20) and an independent validation group (n = 17).

View Article and Find Full Text PDF

Motion-resolved parametric imaging derived from short dynamic [F]FDG PET/CT scans.

Phys Med

July 2025

Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Groningen 9713 GZ, Netherlands.

Purpose: This study aims to assess the added value of utilizing short-dynamic whole-body PET/CT scans and implementing motion correction before quantifying metabolic rate, offering more insights into physiological processes. While this approach may not be commonly adopted, addressing motion effects is crucial due to their demonstrated potential to cause significant errors in parametric imaging.

Methods: A 15-minute dynamic FDG PET acquisition protocol was utilized for four lymphoma patients undergoing therapy evaluation.

View Article and Find Full Text PDF

Feasibility of simplified Patlak parametric imaging with scaled population-based input function on pancreatic cancer.

EJNMMI Phys

May 2025

Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Center for Rare Diseases Research, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Un

Background: This study evaluates the feasibility of using a simplified Patlak parametric imaging technique with a scaled population-based input function (sPBIF) in pancreatic cancer.

Methods: Twenty-six patients underwent multi-bed, multi-pass [F]FDG PET/CT scans, from which both dynamic and static PET images were reconstructed. Patlak parametric images were generated from the dynamic PET series using both the image-derived input function (IDIF) and the sPBIF.

View Article and Find Full Text PDF

Parametric imaging from dynamic positron emission tomography (PET) has gained interest for tumour diagnostics and treatment response evaluation. However, the lack of a standardized method for generating the-reference curve for kinetic modelling-has led to inconsistent descriptors, contributing to uncertainties in parametric imaging reliability. This study aims to address this challenge by proposing a hyperparametric optimization method for deriving FDG population-based input function (PBIF), independent of acquisition and injection protocols.

View Article and Find Full Text PDF