Article Abstract

Purpose: This study aimed to compare the resting energy expenditure (REE) measured using indirect calorimetry with that estimated using predictive equations in severe trauma patients to determine the appropriate caloric requirements.

Methods: Patients admitted to the surgical intensive care unit between January 2020 and March 2023 were included in this study. Indirect calorimetry was used to measure the patients' REE values. These values were subsequently compared with those estimated using predictive equations: the weight-based equation (rule of thumb, 25 kcal/kg/day), Harris-Benedict, Ireton-Jones, and the Penn State 2003 equations.

Results: A total of 27 severe trauma patients were included in this study, and 47 indirect calorimetric measurements were conducted. The weight-based equation (mean difference [MD], -28.96±303.58 kcal) and the Penn State 2003 equation (MD, -3.56±270.39 kcal) showed the closest results to REE measured by indirect calorimetry. However, the REE values estimated using the Harris-Benedict equation (MD, 156.64±276.54 kcal) and Ireton-Jones equation (MD, 250.87±332.54 kcal) displayed significant differences from those measured using indirect calorimetry. The concordance rate, which the predictive REE differs from the measured REE value within 10%, was up to 36.2%.

Conclusions: The REE values estimated using predictive equations exhibited substantial differences from those measured via indirect calorimetry. Therefore, it is necessary to measure the REE value through indirect calorimetry in severe trauma patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11309252PMC
http://dx.doi.org/10.20408/jti.2023.0051DOI Listing

Publication Analysis

Top Keywords

indirect calorimetry
28
severe trauma
16
trauma patients
16
measured indirect
16
estimated predictive
12
predictive equations
12
ree values
12
resting energy
8
energy expenditure
8
indirect
8

Similar Publications

This rapid systematic review aimed to evaluate the diagnostic accuracy (concurrent validity, predictive ability, reliability) of indirect calorimetry (IC) for measuring resting energy expenditure (REE) in adults with overweight or obesity. PubMed and Web of Science searched for studies measuring REE by IC in adults with overweight or obesity and reported primary outcomes: concurrent validity, predictive ability, or reliability. N = 22 studies were included that evaluated n = 10 IC devices.

View Article and Find Full Text PDF

Methane (CH), carbon dioxide (CO), and oxygen (O) are the major gases produced by dairy cattle as a result of rumen fermentation and metabolism, and thus, their concentrations are frequently measured as a way of estimating heat production and energy metabolism. A well-utilized method of measuring gas consumption and production to estimate heat production is indirect calorimetry, which requires bags to retain the sampled gases until analysis. The objective of this study was to determine the ability of a polyvinyl fluoride gas bag (PF) and a multilayer fabrication gas bag containing an aluminum layer (NAP) to maintain respiratory gas composition in comparison to a polyethylene terephthalate bag (PET).

View Article and Find Full Text PDF

Boosting biocompatibility and minimizing inflammation in electrospun polyvinylidene fluoride (PVDF) cardiac patches through optimized low-pressure plasma treatment.

Biomater Adv

September 2025

Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Torino, Italy.

Tailoring surface characteristics is key to guiding scaffold interaction with the biological environment, promoting successful biointegration while minimizing immune responses and inflammation. In cardiac tissue engineering, polyvinylidene fluoride (PVDF) is a material of choice for its intrinsic piezoelectric properties, which can be enhanced through electrospinning, also enabling the fabrication of nanofibrous structures mimicking native tissue. However, the inherent hydrophobicity of PVDF can hinder its integration with biological tissues.

View Article and Find Full Text PDF

In an interplay with parenchymal cells of metabolically active organs such as heart and adipose tissues, vascular endothelial cells are important for the regulation of nutrient uptake and organ-specific energy metabolism. Based on high expression of the scavenger receptor B1 (SR-B1) in capillary endothelial cells of white and brown adipose tissue (BAT), we proposed a functional role for this receptor in lipid handling and adaptive thermogenesis. To address this hypothesis, we generated mice with an endothelial-specific knockout of SR-B1 and performed metabolic turnover and indirect calorimetry studies in response to environmental cues such as cold exposure and high fat diet feeding.

View Article and Find Full Text PDF

The lethal yellow (A) mutation in the Raly-Agouti locus leads to ectopic expression of the agouti protein in the brain where it inhibits melanocortin receptors, causes obesity as well as alters some traits of adaptive behavior. In the present study we used the Phenomaster calorimetric module tool to compare the travel distance, food and O consumption as well as CO excretion in 12 weeks old males of C57BL/6- A and C57BL/6 mice. The A mutation did not affect travelled distance and food consumption.

View Article and Find Full Text PDF