A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Segmentation and multiparametric evaluation of corneal whorl-like nerves for in vivo confocal microscopy images in dry eye disease. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To establish an automated corneal nerve analysis system for corneal in vivo confocal microscopy (IVCM) images from both the whorl-like corneal nerves in the inferior whorl (IW) region and the straight ones in the central cornea and to characterise the geometric features of cornea nerves in dry eye disease (DED).

Methods And Analysis: An encoder-decoder-based semi-supervised method was proposed for corneal nerve segmentation. This model's performance was compared with the ground truth provided by experienced clinicians, using Dice similarity coefficient (DSC), mean intersection over union (mIoU), accuracy (Acc), sensitivity (Sen) and specificity (Spe). The corneal nerve total length (CNFL), tortuosity (CNTor), fractal dimension (CND) and number of branching points (CNBP) were used for further analysis in an independent DED dataset including 50 patients with DED and 30 healthy controls.

Results: The model achieved 95.72% Acc, 97.88% Spe, 80.61% Sen, 75.26% DSC, 77.57% mIoU and an area under the curve value of 0.98. For clinical evaluation, the CNFL, CNBP and CND for whorl-like and straight nerves showed a significant decrease in DED patients compared with healthy controls (p<0.05). Additionally, significantly elevated CNTor was detected in the IW in DED patients (p<0.05). The CNTor for straight corneal nerves, however, showed no significant alteration in DED patients (p>0.05).

Conclusion: The proposed method segments both whorl-like and straight corneal nerves in IVCM images with high accuracy and offered parameters to objectively quantify DED-induced corneal nerve injury. The IW is an effective region to detect alterations of multiple geometric indices in DED patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11459327PMC
http://dx.doi.org/10.1136/bmjophth-2024-001861DOI Listing

Publication Analysis

Top Keywords

corneal nerve
12
vivo confocal
8
confocal microscopy
8
dry eye
8
eye disease
8
corneal
6
segmentation multiparametric
4
multiparametric evaluation
4
evaluation corneal
4
corneal whorl-like
4

Similar Publications