Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To develop a 3D free-breathing cardiac multi-parametric mapping framework that is robust to confounders of respiratory motion, fat, and B1+ inhomogeneities and validate it for joint myocardial T1 and T1ρ mapping at 3T.

Methods: An electrocardiogram-triggered sequence with dual-echo Dixon readout was developed, where nine cardiac cycles were repeatedly acquired with inversion recovery and T1ρ preparation pulses for T1 and T1ρ sensitization. A subject-specific respiratory motion model relating the 1D diaphragmatic navigator to the respiration-induced 3D translational motion of the heart was constructed followed by respiratory motion binning and intra-bin 3D translational and inter-bin non-rigid motion correction. Spin history B1+ inhomogeneities were corrected with optimized dual flip angle strategy. After water-fat separation, the water images were matched to the simulated dictionary for T1 and T1ρ quantification. Phantoms and 10 heathy subjects were imaged to validate the proposed technique.

Results: The proposed technique achieved strong correlation (T1: R = 0.99; T1ρ: R = 0.98) with the reference measurements in phantoms. 3D cardiac T1 and T1ρ maps with spatial resolution of 2 × 2 × 4 mm were obtained with scan time of 5.4 ± 0.5 min, demonstrating comparable T1 (1236 ± 59 ms) and T1ρ (50.2 ± 2.4 ms) measurements to 2D separate breath-hold mapping techniques. The estimated B1+ maps showed spatial variations across the left ventricle with the septal and inferior regions being 10%-25% lower than the anterior and septal regions.

Conclusion: The proposed technique achieved efficient 3D joint myocardial T1 and T1ρ mapping at 3T with respiratory motion correction, spin history B1+ correction and water-fat separation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.30317DOI Listing

Publication Analysis

Top Keywords

respiratory motion
20
myocardial t1ρ
12
t1ρ mapping
12
motion correction
12
water-fat separation
12
t1ρ
9
subject-specific respiratory
8
correction water-fat
8
b1+ inhomogeneities
8
joint myocardial
8

Similar Publications

Background: In clinical practice, digital subtraction angiography (DSA) often suffers from misregistration artifact resulting from voluntary, respiratory, and cardiac motion during acquisition. Most prior efforts to register the background DSA mask to subsequent postcontrast images rely on key point registration using iterative optimization, which has limited real-time application.

Purpose: Leveraging state-of-the-art, unsupervised deep learning, we aim to develop a fast, deformable registration model to substantially reduce DSA misregistration in craniocervical angiography without compromising spatial resolution or introducing new artifacts.

View Article and Find Full Text PDF

Background: Understanding respiratory motions of liver and its surrogate organs is crucial for precise dose delivery in liver cancer radiotherapy. Although these motions have been studied for respiratory motion management in the supine posture, few studies have quantified them and evaluated their correlations in the upright posture.

Purpose: This study quantified the respiratory motions of liver and surrogate organs and evaluated the correlations between the liver motions and surrogate signals for respiratory motion monitoring in both the supine and upright postures.

View Article and Find Full Text PDF

Background: Four-dimensional magnetic resonance imaging (4D-MRI) holds great promise for precise abdominal radiotherapy guidance. However, current 4D-MRI methods are limited by an inherent trade-off between spatial and temporal resolutions, resulting in compromised image quality characterized by low spatial resolution and significant motion artifacts, hindering clinical implementation. Despite recent advancements, existing methods inadequately exploit redundant frame information and struggle to restore structural details from highly undersampled acquisitions.

View Article and Find Full Text PDF

Understanding gastric physiology in rodents is critical for advancing preclinical neurogastroenterology research. However, existing techniques are often invasive, terminal, or limited in resolution. This study aims to develop a non-invasive, standardized MRI protocol capable of capturing whole-stomach dynamics in anesthetized rats with high spatiotemporal resolution.

View Article and Find Full Text PDF

Background: Stereotactic body radiotherapy (SBRT) is an effective treatment for early-stage non-small cell lung cancer. However, patient breathing can affect treatment accuracy. Therefore, this study aimed to develop a bi-polar (BP) gated motion management strategy for SBRT and evaluate its feasibility geometrically and dosimetrically.

View Article and Find Full Text PDF