A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Cross-reactivity between thiuram disulfides and dithiocarbamates. A study of TETD and ZDEC using mouse models. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Rubber accelerators are used in the vulcanization of rubber. However, rubber accelerators for example tetraethylthiuram disulfide (TETD) and zinc diethyldithiocarbamate (ZDEC) may cause contact allergy. Concomitant reactions between ZDEC and TETD have been observed in patients which could be explained by co- or cross-reactivity.

Objectives: To investigate cross-reactivity between TETD and ZDEC and vice versa.

Methods: Groups of mice were sensitized with TETD or ZDEC based on reported EC3-values. Proliferation of lymphocytes were measured on day 5. To test cross-reactivity, mice were sensitized and challenged 3 weeks later with TETD or ZDEC. The inflammatory response was measured by changes in ear thickness and the proliferative response in CD4 and CD8 T cells in the submandibular and cervical draining lymph nodes.

Results: Sensitization of mice with doses of ZDEC 3%, TETD 5.6% or TETD 16.2% induced significant increased ear thickness and proliferation of CD4 and CD8 T cells. Challenge with ZDEC or TETD in these groups induced significant increased ear thickness. Challenge with ZDEC in mice sensitized to TETD 5.6% or TETD 16.2% induced significant increased proliferation of CD4 and CD8 T cells.

Conclusions: We show cross-reactivity between TETD and ZDEC. Patients sensitized to TETD or ZDEC should avoid exposure to both ZDEC and TETD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11710922PMC
http://dx.doi.org/10.1111/cod.14706DOI Listing

Publication Analysis

Top Keywords

tetd zdec
24
zdec tetd
16
tetd
14
zdec
12
mice sensitized
12
sensitized tetd
12
ear thickness
12
cd4 cd8
12
induced increased
12
rubber accelerators
8

Similar Publications