A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Kinematical Effects of a Mandibular Advancement Occlusal Splint on Running until Exhaustion at Severe Intensity. | LitMetric

Kinematical Effects of a Mandibular Advancement Occlusal Splint on Running until Exhaustion at Severe Intensity.

Sensors (Basel)

Centre of Research, Education, Innovation and Intervention in Sport, CIFI2D, and Porto Biomechanics Laboratory, LABIOMEP-UP, Faculty of Sport, University of Porto, 4200-450 Porto, Portugal.

Published: September 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The effects of occlusal splints on sport performance have already been studied, although their biomechanical impacts are often overlooked. We investigated the kinematical changes during running until exhaustion at severe intensity while wearing a mandibular advancement occlusal splint. Twelve trained runners completed (i) an incremental protocol on a track to determine their velocity corresponding to maximal oxygen uptake and (ii) two trials of square wave transition exercises at their velocity corresponding to maximal oxygen until exhaustion, wearing two occlusal splints (without and with mandibular advancement). Running kinematics were compared within laps performed during the square wave transition exercises and between splint conditions. The mandibular advancement occlusal splint increased the running distance covered (~1663 ± 402 vs. 1540 ± 397 m, = 0.03), along with a noticeable lap effect in decreasing stride frequency ( = 0.04) and increasing stride length ( = 0.03) and duty factor ( 0.001). No spatiotemporal differences were observed between splints, except for improved balance foot contact times in the mandibular advancement condition. An increased knee flexion angle at initial contact ( = 0.017) was noted along laps in the non-advancement condition, despite the fact that no differences between splints were found. Running patterns mainly shifted within laps rather than between conditions, indicating that a mandibular advancement occlusal splint had a trivial kinematical effect.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11435913PMC
http://dx.doi.org/10.3390/s24186032DOI Listing

Publication Analysis

Top Keywords

mandibular advancement
24
advancement occlusal
16
occlusal splint
16
running exhaustion
8
exhaustion severe
8
severe intensity
8
occlusal splints
8
velocity corresponding
8
corresponding maximal
8
maximal oxygen
8

Similar Publications