A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Isometric Midthigh-Pull Testing: Reliability and Correlation With Key Functional Capacities in Young Soccer Players. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: We examined the reliability of force parameters derived from the isometric midthigh pull (IMTP) and their correlation with the functional capacities of young soccer players.

Methods: Data were collected from 20 young professional soccer players within and between 2 sessions (after 1 wk) using a 1000-Hz force plate.

Results: Performance outputs in all IMTP parameters were consistent and showed moderate to excellent reliability (intraclass correlation coefficient = .72-1.00) within and between sessions. However, all parameters reported a marginal ability to detect chronic changes in performance (smallest worthwhile change [SWC] < standard error of measurement [SEM]) except for peak vertical force (PF) parameters, which showed good usefulness (SWC > SEM). Absolute PF was correlated with the countermovement-jump (CMJ) total impulse (CMJ-TI; r = .54), whereas relative PF (to body mass) was correlated with CMJ height, CMJ peak power, and the last speed of the 30:15 Intermittent Fitness Test (VIFT; r = .40 to .63). IMTP time-dependent forces were correlated with CMJ-TI (r = .52 to .62). The IMTP impulse parameters were positively correlated with CMJ-TI (r = .48 to .58) and negatively with VIFT (r = -.44 to -.38). None of the IMTP parameters were correlated either with the CMJ mean propulsive force or with any linear acceleration times.

Conclusions: All IMTP parameters can be adopted by practitioners involved with testing young soccer players based on their acceptable reliability criteria. However, caution should be taken when interpreting the time-dependent variables based on their marginal usefulness when assessing performance. Generally, a greater PF was associated with a greater vertical power based on its correlation to CMJ.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijspp.2024-0203DOI Listing

Publication Analysis

Top Keywords

young soccer
12
soccer players
12
imtp parameters
12
functional capacities
8
capacities young
8
force parameters
8
correlated cmj
8
correlated cmj-ti
8
parameters
7
imtp
6

Similar Publications