Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11412764PMC
http://dx.doi.org/10.1055/a-2408-9787DOI Listing

Publication Analysis

Top Keywords

traction method
8
novel traction
4
method multi-loop
4
multi-loop traction
4
traction device
4
device colorectal
4
colorectal endoscopic
4
endoscopic submucosal
4
submucosal dissection
4
dissection anchor
4

Similar Publications

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF

Purpose: To describe the clinical and multimodal imaging features of a novel form of macular neovascularization (MNV), designated Type 4 MNV, defined by mixed Type 1 and Type 2 neovascularization (NV), extensive intraretinal anastomotic NV, and central posterior hyaloid fibrosis (CPHF).

Methods: This multicenter retrospective observational case series included patients with neovascular age-related macular degeneration (AMD) exhibiting both Type 1 and 2 MNV and an overlying anastomotic intraretinal NV network. This was confirmed with OCT and OCT angiography (OCTA).

View Article and Find Full Text PDF

Natural history of tractional lamellar macular hole.

Retina

September 2025

Department of Ophthalmology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.

Purpose: To evaluate the long-term functional and anatomical outcomes in patients with tractional lamellar macular holes who were managed without surgical intervention.

Methods: 63 eyes previously diagnosed with tractional lamellar macular hole between July 1, 2009 and January 30, 2024 without any surgical interventions were enrolled. The change in best-corrected visual acuity (BCVA), lamellar hole diameter, central retinal thickness (CRT) on Optical coherence tomography (OCT), foveal avascular zone (FAZ) areas on OCT angiography, and M-chart scores between initial and final visit were assessed.

View Article and Find Full Text PDF

Swept Source Optical Coherence Tomography Imaging of the Optic Pit Complex.

Retina

September 2025

From the Vitreous, Retina, Macula Consultants of New York, New York, NY.

Purpose: To reassess the anatomic basis of optic disc pit maculopathy (OPM) using swept-source optical coherence tomography (SS-OCT) and to characterize the broader structural abnormalities comprising the optic pit complex.

Methods: Sixteen patients with OPM were imaged using a high-resolution SS-OCT system (DREAM OCT). Cross-sectional and volume-rendered scans were analyzed for lamina cribrosa defects, intraneural cavitations, and pathways for fluid entry into or beneath the retina.

View Article and Find Full Text PDF

Purpose: To investigate associations among expanded field swept-source optical coherence tomography angiography (SS-OCTA) biomarkers and the development of tractional retinal detachment (TRD) in patients with proliferative diabetic retinopathy (PDR).

Methods: Patients with PDR without TRD at baseline were imaged with SS-OCTA. Quantitative and qualitative OCTA metrics were independently evaluated by two trained graders.

View Article and Find Full Text PDF