A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Gyroscope-Assisted CT-Guided Puncture Improves Accuracy and Hit Rate Compared with Free-Hand Puncture: A Phantom Study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate gyroscope-assisted CT-guided needle puncture (GAP) compared to free hand puncture (FHP) in a phantom.

Material And Methods: A simple, low-cost gyroscope was equipped with a magnetic rail to attach it to common puncture needles. 18 radiologists with different levels of training and experience in CT-guided punctures first punctured three targets in free hand technique in a special biopsy phantom with different difficulty levels of the puncture path (T1: not angulated, needle path 7.3 cm, size 15 mm in diameter, T2: single angulated 41°, needle path 11.3 cm, size 9 mm in diameter, T3: double angulated 38°/26°, needle path 7 cm, size 8 mm in diameter). Without knowing the result of the puncture, a second puncture was performed directly afterwards with the aid of the gyroscope. Punctures were performed in a continuous procedure without intermediate control. The hit rate and the distance between the needle tip and the center of the lesion were evaluated. Additionally, the time needed for the procedure was measured.

Results: Thirty-three of 54 insertions (61.1%) hit the target in GAP compared to 20 of 54 (37%) in FHP (p = 0.002). The mean distance of the needle tip to the lesion center was 7.49 ± 5.31 mm in GAP compared to 13.37 ± 10.24 mm in FHP (p < 0.001). Puncture time was not significantly different between GAP (36.72 ± 20.38 s) and FHP (37.83 ± 20.53 s) (p = 0.362).

Conclusion: Needle guidance with a gyroscope enables an improved hit rate and puncture accuracy in CT-guided punctures without prolonging the puncture time. The needle guidance by gyroscope is inexpensive and easy to establish.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-024-03832-8DOI Listing

Publication Analysis

Top Keywords

gap compared
12
needle path
12
gyroscope-assisted ct-guided
8
puncture
8
hit rate
8
free hand
8
distance needle
8
needle
6
ct-guided puncture
4
puncture improves
4

Similar Publications