A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Impact of Aficamten on Echocardiographic Cardiac Structure and Function in Symptomatic Obstructive Hypertrophic Cardiomyopathy. | LitMetric

Article Synopsis

  • Aficamten, a new cardiac myosin inhibitor, was tested in a Phase 3 trial (SEQUOIA-HCM) and effectively improved peak oxygen uptake and reduced left ventricular outflow gradients in adults with obstructive hypertrophic cardiomyopathy.
  • Serial echocardiograms over 28 weeks showed that aficamten significantly improved various echocardiographic measures, including left atrial volume and strain, while also reducing LVOT gradients.
  • The treatment resulted in a mild, reversible decrease in left ventricular ejection fraction, and post-treatment measures returned to baseline, indicating temporary effects on heart function.

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Aficamten, a next-in-class cardiac myosin inhibitor, improved peak oxygen uptake (pVO) and lowered resting and Valsalva left ventricular outflow (LVOT) gradients in adults with symptomatic obstructive hypertrophic cardiomyopathy (oHCM) in SEQUOIA-HCM (Phase 3 Trial to Evaluate the Efficacy and Safety of Aficamten Compared to Placebo in Adults With Symptomatic oHCM), a phase 3, multicenter, randomized, double-blinded, placebo-controlled study.

Objectives: The authors sought to evaluate the effect of aficamten on echocardiographic measures of cardiac structure and function in SEQUOIA-HCM.

Methods: Serial echocardiograms were performed over 28 weeks in patients randomized to receive placebo or aficamten in up to 4 individually titrated escalating doses (5-20 mg daily) over 24 weeks based on Valsalva LVOT gradients and left ventricular ejection fraction (LVEF).

Results: Among 282 patients (mean age 59 ± 13 years; 41% female, 79% White, 19% Asian), mean LVEF was 75% ± 6% with resting and Valsalva LVOT gradients of 55 ± 30 mm Hg and 83 ± 32 mm Hg, respectively. Over 24 weeks, aficamten significantly lowered resting and Valsalva LVOT gradients, and improved left atrial volume index, lateral and septal e' velocities, and lateral and septal E/e' (all P ≤ 0.001). LV end-systolic volume increased and wall thickness decreased (all P ≤ 0.003). Aficamten resulted in a mild reversible decrease in LVEF (-4.8% [95% CI: -6.4% to -3.3%]; P < 0.001) and absolute LV global circumferential strain (-3.7% [95% CI: 1.8%-5.6%]; P < 0.0010), whereas LV global longitudinal strain was unchanged. Several measures, including LVEF, LVOT gradients, and E/e' returned to baseline following washout. Among those treated with aficamten, improved pVO and reduction in N-terminal pro-B-type natriuretic peptide (NT-proBNP) were associated with improvement in lateral e' velocity and septal and lateral E/e' (all P < 0.03), whereas improvement in Kansas City Cardiomyopathy Questionnaire Clinical Summary Scores (KCCQ-CSS) was associated with a decrease in both LVOT gradients (all P < 0.001).

Conclusions: Compared with placebo, patients receiving aficamten demonstrated significant improvement in LVOT gradients and measures of LV diastolic function, and several of these measures were associated with improvements in pVO, KCCQ-CSS, and NT-proBNP. A modest decrease in LVEF occurred yet remained within normal range. These findings suggest aficamten improved multiple structural and physiological parameters in oHCM without significant adverse changes in LV systolic function. (Phase 3 Trial to Evaluate the Efficacy and Safety of Aficamten Compared to Placebo in Adults With Symptomatic oHCM [SEQUOIA-HCM]; NCT05186818).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2024.08.002DOI Listing

Publication Analysis

Top Keywords

lvot gradients
16
resting valsalva
12
valsalva lvot
12
aficamten echocardiographic
8
cardiac structure
8
structure function
8
symptomatic obstructive
8
obstructive hypertrophic
8
hypertrophic cardiomyopathy
8
lowered resting
8

Similar Publications