Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Percutaneous endoscopic gastrostomy is commonly used for enteral nutritional access, but gastrocutaneous fistulae (GCF) may persist after tube removal, posing clinical challenges. The use of endoscopic closure devices, including over-the-scope clips (OTSC), has shown promise in managing non-healing fistulae, although data in the pediatric population are limited.

Methods: A retrospective multicenter study analyzed pediatric patients who underwent GCF closure following gastrostomy tube removal. Data from seven centers across multiple countries were collected, including patient demographics, procedural details, complications, and outcomes. Closure techniques were compared between OTSC and surgical closure.

Results: Of 67 pediatric patients included, 21 underwent OTSC closure and 46 had surgical closure. Surgical closure demonstrated a higher success rate (100%) compared to OTSC closure (61.9%, P < 0.001). While procedural duration was shorter for OTSC closure (25 vs. 40 min, P = 0.002), complications, and scar quality were comparable between techniques. A subsequent sub-analysis did not reveal differences based on center experience.

Conclusion: OTSC closure is feasible and safe in pediatric patients, but surgical closure remains superior in achieving sustained GCF closure, although OTSC offers benefits, such as shorter procedural duration, potentially reducing the duration of general anesthesia exposure. Non-operative approaches, including OTSC, may be a valuable alternative to surgical closure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11525288PMC
http://dx.doi.org/10.1007/s00464-024-11166-2DOI Listing

Publication Analysis

Top Keywords

tube removal
12
closure
8
gastrostomy tube
8
pediatric patients
8
compared otsc
8
otsc closure
8
closure surgical
8
surgical closure
8
over-the-scope clip
4
clip closure
4

Similar Publications

We report a rare case in which the inflation lumen at the tip of an endotracheal tube (ETT) was open, leading to intraoperative air leakage and cuff deflation. A patient with Down syndrome undergoing planned dental treatment under general anesthesia was induced and nasally intubated with a cuffed ETT that was then inflated with 5 mL of air. Soon thereafter, it was noted that the pilot balloon was deflated and filled with water droplets.

View Article and Find Full Text PDF

Objective: Persistent pulmonary air leak happens in a minority of patients with various thoracic pathologies. Spiration (Olympus America Inc.) bronchial valves (BVs) are approved by the Food and Drug Administration under Humanitarian Use Device status to treat persistent air leak after lung resection.

View Article and Find Full Text PDF

Pressure-dependent pneumothorax is an under-recognized but clinically significant phenomenon that complicates pleural fluid drainage, particularly in patients with non-expandable lungs due to malignancy or chronic pleural fibrosis. Unlike pressure-independent pneumothorax, this condition arises from the pronounced transpleural pressure gradient generated during therapeutic thoracentesis or chest drainage. This negative pressure transiently distorts the visceral pleura, allowing air to enter the pleural space until an equilibrium is reached.

View Article and Find Full Text PDF

Electrochemical grooving of tube inner walls with emphasis on feed strategy and multi-pass effects on material removal and groove geometry.

PLoS One

September 2025

Department of Mechanical Engineering, Faculty of Engineering and Natural Sciences, Samsun University, Samsun, Turkiye.

Electrochemical (EC) grooving minimises tool wear and residual stress when machining hard-to-cut tube materials. This study examines how the number of passes and tool feed direction affect material removal rate (MRR) and removed area (RA) in Stellite 21 tubes. Two feed strategies were tested: Unidirectional Electrolyte Flow (UEF), where the tool moves entirely opposite to the electrolyte flow; and Hybrid Electrolyte Flow (HEF), where the tool first moves against and then with the flow direction.

View Article and Find Full Text PDF

Introduction: Endotracheal tube (ETT) cuff pressures that exceed 20-30 cmHO may lead to iatrogenic adverse effects such as cough, sore throat, and tracheal edema or more serious complications including tracheal stenosis, recurrent laryngeal nerve injury, and tracheal rupture. The current study evaluates a novel technique, titration of the ratio of expiratory to inspiratory tidal volumes (TV), to regulate intracuff pressure.

Methods: This prospective, cross-over trial measured intracuff pressure in a cohort of pediatric patients presenting for general anesthesia with an ETT.

View Article and Find Full Text PDF